Generalized Ramsey Excitation Scheme with Suppressed Light Shift
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We experimentally investigate a recently proposed optical excitation scheme V. I. Yudin et al. [Phys. Rev. A 82, 011804(R) (2010)] that is a generalization of Ramsey's method of separated oscillatory fields and consists of a sequence of three excitation pulses. The pulse sequence is tailored to produce a resonance signal that is immune to the light shift and other shifts of the transition frequency that are correlated with the interaction with the probe field. We investigate the scheme using a single trapped ^{171}Yb^{+} ion and excite the highly forbidden (2)S(1/2) - (2)F(7/2) electric-octupole transition under conditions where the light shift is much larger than the excitation linewidth, which is in the hertz range. The experiments demonstrate a suppression of the light shift by four orders of magnitude and an immunity against its fluctuations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum computing with trapped ions
HAFFNER, H., ROOS, C., & BLATT, R. (2008) · Physics Reports · doi:10.1016/j.physrep.2008.09.003 · Cited by 1,154
Accuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationSingle-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468
Improved Limit on a Temporal Variation ofmp/mefrom Comparisons ofYb+and Cs Atomic Clocks
Huntemann, N., Lipphardt, B., Tamm, C., Gerginov, V., Weyers, S., & Peik, E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210802 · Cited by 366
Self-citationHighly charged ions: Optical clocks and applications in fundamental physics
Kozlov, M. G., Safronova, M. S., Crespo López-Urrutia, J. R., & Schmidt, P. O. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.045005 · Cited by 311
Metadata
- Authors
- Huntemann, N., Lipphardt, B., Okhapkin, M., Tamm, C., Peik, E., Taichenachev, A. V., & Yudin, V. I.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-11-21
- Volume
- 109
- Issue
- 21
- Pages
- 213002-213002
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2073675750
- Cited by
- 112
- References
- 2
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.