Cited by 468Advanced Frequency and Time StandardsScientific Measurement and Uncertainty EvaluationAtomic and Molecular Physics

Frequency Ratio of Two Optical Clock Transitions inYb+171and Constraints on the Time Variation of Fundamental Constants

Open access
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N. +2 more·2014·Physical Review Letters

Abstract

Singly ionized ytterbium, with ultranarrow optical clock transitions at 467 and 436 nm, is a convenient system for the realization of optical atomic clocks and tests of present-day variation of fundamental constants. We present the first direct measurement of the frequency ratio of these two clock transitions, without reference to a cesium primary standard, and using the same single ion of 171Yb+. The absolute frequencies of both transitions are also presented, each with a relative standard uncertainty of 6×10(-16). Combining our results with those from other experiments, we report a threefold improvement in the constraint on the time variation of the proton-to-electron mass ratio, μ/μ=0.2(1.1)×10(-16) yr(-1), along with an improved constraint on time variation of the fine structure constant, α/α=-0.7(2.1)×10(-17) yr(-1).

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.113.210801

Cites

52 of 52 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Comparing resonance frequencies of optical clocks has led to new tests of fundamental physics, such as bounding the time variation of fundamental constants.

    “Thanks to these unparalleled performances, comparing the resonance frequencies of optical clocks has led to new tests of fundamental physics, such as bounding the time variation of fundamental constants [7,8].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 6

  1. [8]J. Gu´ ena, M. Abgrall, D. Rovera, P. Laurent, B. Chupin, M. Lours, G. Santarelli, P. Rosenbusch, M. E. Tobar, R. Li, K. Gibble, A. Clairon, and S. Bize, IEEE Trans. Ultrason. Ferroelec. Freq. Cont. 59 , 391 (2012).
  2. [10]S. Webster, R. Godun, S. King, G. Huang, B. Walton, V. Tsatourian, H. Margolis, S. Lea, and P. Gill, IEEE Trans. Ultrason. Ferroelec. Freq. Cont. 57 , 592 (2010).
  3. [20]K. Hosaka, S. A. Webster, P. J. Blythe, A. Stannard, D. Beaton, H. S. Margolis, S. N. Lea, and P. Gill, IEEE Trans. Inst. Meas. 54 , 759 (2005).
  4. [24]L. A. M. Johnson, P. Gill, and H. S. Margolis, arXiv:1408.2387 (2014). · arXiv
  5. [26]K. Szymaniec, S. N. Lea, and K. Liu, IEEE Trans. Ultrason. Ferroelec. Freq. Cont. 61 , 203 (2014).
  6. [52]N. Huntemann, B. Lipphardt, C. Tamm, V. Gerginov, S. Weyers, and E. Peik, arXiv:1407.4408 (2014). · arXiv

Cited by

Sorted by citations

Authors
Godun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P.
Affiliations
  • National Physical Laboratory (GB)
  • University of Birmingham (GB)
Venue
Physical Review Letters
Published
2014-11-17
Volume
113
Issue
21
Pages
210801-210801
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2072099674
Cited by
468
References
52
Citations by year
2026: 13 · 2025: 39 · 2024: 40 · 2023: 40 · 2022: 28 · 2021: 41 · 2020: 51 · 2019: 45 · 2018: 46 · 2017: 44 · 2016: 46 · 2015: 32 · 2014: 3
FWCI
20.72
Type
journal article
Language
en
Open access
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • European Space Agency
  • UK National Measurement System
  • European Metrology Research Programme
  • EURAMET
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
Keywords
optical atomic clocks, ytterbium-171, frequency ratio measurement, absolute frequency measurement, variation of fundamental constants, proton-electron mass ratio, fine-structure constant

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review