The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
All-Optical Vector Atomic Magnetometer
Open accessAbstract
We demonstrate an all-optical magnetometer capable of measuring the magnitude and direction of a magnetic field using nonlinear magneto-optical rotation in cesium vapor. Vector capability is added by effective modulation of the field along orthogonal axes and subsequent demodulation of the magnetic-resonance frequency. This modulation is provided by the ac Stark shift induced by circularly polarized laser beams. The sensor exhibits a demonstrated rms noise floor of $\ensuremath{\sim}65\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ in measurement of the field magnitude and $0.5\text{ }\text{ }\mathrm{mrad}/\sqrt{\mathrm{Hz}}$ in the field direction; elimination of technical noise would improve these sensitivities to $12\text{ }\text{ }\mathrm{fT}/\sqrt{\mathrm{Hz}}$ and $10\text{ }\text{ }\ensuremath{\mu}\mathrm{rad}/\sqrt{\mathrm{Hz}}$, respectively. Applications for this all-optical vector magnetometer would include magnetically sensitive fundamental physics experiments, such as the search for a permanent electric dipole moment of the neutron.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
Self-citationPrinciples of Operation of the Rubidium Vapor Magnetometer
Bloom, A. L. (1962) · Applied Optics · doi:10.1364/ao.1.000061 · Cited by 282
Cited by
Electric dipole moments of atoms, molecules, nuclei, and particles
Chupp, T. E., Fierlinger, P., Ramsey-Musolf, M. J., & Singh, J. T. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.015001 · Cited by 450
Metadata
- Authors
- Patton, B., Zhivun, E., Hovde, D. C., & Budker, D.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2014-07-01
- Volume
- 113
- Issue
- 1
- Pages
- 013001-013001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1659169028
- Cited by
- 185
- References
- 4
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: All-Optical Vector Atomic Magnetometer. https://app.cochat.ai/papers/10.1103/physrevlett.113.013001
- The paper
- Patton, B., Zhivun, E., Hovde, D. C., & Budker, D. (2014). All-Optical Vector Atomic Magnetometer. Physical Review Letters. https://doi.org/10.1103/physrevlett.113.013001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.