The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Open accessAbstract
We describe an ultrasensitive atomic magnetometer based on optically pumped potassium atoms operating in a spin-exchange relaxation free regime. We demonstrate magnetic field sensitivity of 160 aT/Hz1/2 in a gradiometer arrangement with a measurement volume of 0.45 cm3 and energy resolution per unit bandwidth of 44ℏ. As an example of an application enabled by such a magnetometer, we describe measurements of weak remnant rock magnetization as a function of temperature with a sensitivity on the order of 10−10 emu/cm3/Hz1/2 and temperatures up to 420°C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [33]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationA subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationSingle spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
Spin-exchange optical pumping of noble-gas nuclei
Walker, T. G., & Happer, W. (1997) · Reviews of Modern Physics · doi:10.1103/revmodphys.69.629 · Cited by 1,444
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationPaleomagnetic Principles and Practice
(2003) · Modern Approaches in Geophysics · doi:10.1007/0-306-48128-6 · Cited by 470
High-temperature weak ferromagnetism in a low-density free-electron gas
Young, D. P., Hall, D., Torelli, M. E., Fisk, Z., Sarrao, J. L., Thompson, J. D., Ott, H.-R., Oseroff, S. B., Goodrich, R. G., & Zysler, R. (1999) · Nature · doi:10.1038/17081 · Cited by 430
Ultrasensitive magnetic biosensor for homogeneous immunoassay
Chemla, Y. R., Grossman, H. L., Poon, Y., McDermott, R., Stevens, R., Alper, M. D., & Clarke, J. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.26.14268 · Cited by 421
Highly Sensitive and Easy-to-Use SQUID Sensors
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2007.897403 · Cited by 348
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Boto, E., Meyer, S. S., Shah, V., Alem, O., Knappe, S., Kruger, P., Fromhold, T. M., Lim, M., Glover, P. M., Morris, P. G., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.034 · Cited by 471
Quantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
Electric dipole moments of atoms, molecules, nuclei, and particles
Chupp, T. E., Fierlinger, P., Ramsey-Musolf, M. J., & Singh, J. T. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.015001 · Cited by 450
Metadata
- Authors
- Dang, H. B., Maloof, A. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Maloof, A. C.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-10-11
- Volume
- 97
- Issue
- 15
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2131775935
- Cited by
- 891
- References
- 24
- Citations by year
- 2026: 69 · 2025: 110 · 2024: 104 · 2023: 107 · 2022: 94 · 2021: 77 · 2020: 55 · 2019: 67 · 2018: 34 · 2017: 33 · 2016: 30 · 2015: 26 · 2014: 18 · 2013: 23 · 2012: 25
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Applied Physics Letters (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, magnetic field sensitivity, energy resolution, temperature dependence of magnetization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer. https://app.cochat.ai/papers/10.1063/1.3491215
- The paper
- Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010). Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer. Applied Physics Letters. https://doi.org/10.1063/1.3491215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.