The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Continuous Cold-Atom Inertial Sensor with1 nrad/secRotation Stability
Open accessAbstract
We report the operation of a cold-atom inertial sensor which continuously captures the rotation signal. Using a joint interrogation scheme, where we simultaneously prepare a cold-atom source and operate an atom interferometer (AI), enables us to eliminate the dead times. We show that such continuous operation improves the short-term sensitivity of AIs, and demonstrate a rotation sensitivity of 100 nrad/sec/sqrt[Hz] in a cold-atom gyroscope of 11 cm^{2} Sagnac area. We also demonstrate a rotation stability of 1 nrad/sec at 10^{4} sec of integration time, which represents the state of the art for atomic gyroscopes. The continuous operation of cold-atom inertial sensors will lead to large area AIs at their full sensitivity potential, determined by the quantum noise limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability enhancement by joint phase measurements in a single cold atomic fountain
Meunier, M., Dutta, I., Geiger, R., Guerlin, C., Garrido Alzar, C. L., & Landragin, A. (2014) · Physical Review A · doi:10.1103/physreva.90.063633 · Cited by 40
Self-citation
Metadata
- Authors
- Dutta, I., Savoie, D., Fang, B., Venon, B., Garrido Alzar, C. L., Geiger, R., & Landragin, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2016-05-06
- Volume
- 116
- Issue
- 18
- Pages
- 183003-183003
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2337063547
- Cited by
- 284
- References
- 1
- FWCI
- 17.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.