Ultrasensitive Magnetometer using a Single Atom
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Precision sensing, and in particular high precision magnetometry, is a central goal of research into quantum technologies. For magnetometers, often trade-offs exist between sensitivity, spatial resolution, and frequency range. The precision, and thus the sensitivity of magnetometry, scales as 1/sqrt[T_{2}] with the phase coherence time T_{2} of the sensing system playing the role of a key determinant. Adapting a dynamical decoupling scheme that allows for extending T_{2} by orders of magnitude and merging it with a magnetic sensing protocol, we achieve a measurement sensitivity even for high frequency fields close to the standard quantum limit. Using a single atomic ion as a sensor, we experimentally attain a sensitivity of 4.6 pT/sqrt[Hz] for an alternating-current magnetic field near 14 MHz. Based on the principle demonstrated here, this unprecedented sensitivity combined with spatial resolution in the nanometer range and tunability from direct current to the gigahertz range could be used for magnetic imaging in as of yet inaccessible parameter regimes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giovannetti, V., Lloyd, S., & Maccone, L. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.35 · Cited by 3,894
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631 · cited 1×
“Magnetic field sensitivities in the range of femto- or even sub-femtotesla Hz−1/2 have been reached using superconducting quantum interference devices [8] or atomic magnetometers [9].”
MethodImprovement of Frequency Standards with Quantum Entanglement
Huelga, S. F., Macchiavello, C., Pellizzari, T., Ekert, A. K., Plenio, M. B., & Cirac, J. I. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3865 · Cited by 999 · cited 1×
“The precision, and thus the sensitivity of magnetometry scales as 1/ √ T2 [5] with the phase coherence time, T2, of the sensing system playing the role of a key determinant.”
BackgroundSelf-citationOptimized dynamical decoupling in a model quantum memory
Biercuk, M. J., Uys, H., VanDevender, A. P., Shiga, N., Itano, W. M., & Bollinger, J. J. (2009) · Nature · doi:10.1038/nature07951 · Cited by 654 · cited 1×
“Thus, DD can be used to extract information about the magnetic noise spectrum [21, 22], and to improve the signal-to-noise ratio (SNR) in magnetic sensing by several orders of magnitude.”
BackgroundQuantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Blueprint for a microwave trapped ion quantum computer
Lekitsch, B., Weidt, S., Fowler, A. G., Mølmer, K., Devitt, S. J., Wunderlich, C., & Hensinger, W. K. (2017) · Science Advances · doi:10.1126/sciadv.1601540 · Cited by 292
Self-citationInterface between Trapped-Ion Qubits and Traveling Photons with Close-to-Optimal Efficiency
Schupp, J., Krcmarsky, V., Krutyanskiy, V., Meraner, M., Northup, T. E., & Lanyon, B. P. (2021) · PRX Quantum · doi:10.1103/prxquantum.2.020331 · Cited by 94
Estimation of gradients in quantum metrology
Altenburg, S., Oszmaniec, M., Wölk, S., & Gühne, O. (2017) · Physical Review A · doi:10.1103/physreva.96.042319 · Cited by 23
Metadata
- Authors
- Baumgart, I., Cai, J.-M., Retzker, A., Plenio, M. B., & Wunderlich, C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2016-06-17
- Volume
- 116
- Issue
- 24
- Pages
- 240801-240801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1832870444
- Cited by
- 106
- References
- 5
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasensitive Magnetometer using a Single Atom. https://app.cochat.ai/papers/10.1103/physrevlett.116.240801
- The paper
- Baumgart, I., Cai, J.-M., Retzker, A., Plenio, M. B., & Wunderlich, C. (2016). Ultrasensitive Magnetometer using a Single Atom. Physical Review Letters. https://doi.org/10.1103/physrevlett.116.240801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.