Atom-Chip Fountain Gravimeter
Open accessThe DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
We demonstrate a quantum gravimeter by combining the advantages of an atom chip for the generation, delta-kick collimation, and coherent manipulation of freely falling Bose-Einstein condensates (BECs) with an innovative launch mechanism based on Bloch oscillations and double Bragg diffraction. Our high-contrast BEC interferometer realizes tens of milliseconds of free fall in a volume as little as a one centimeter cube and paves the way for measurements with sub-μGal accuracies in miniaturized, robust devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377 · cited 8×
“In a MZI the phase shift ϕ ¼ keffgT2 due to the gravitational acceleration g scales with the square of the free evolution time T between two Bragg processes and linearly with the atomic momentum ℏkeff ¼ 2nℏk transferred by the beam splitter, which depends on Planck’s constant ℏ, the lattice wave vector k ¼ 2π=λ as wel…”
BackgroundInfluentialBloch Oscillations of Atoms in an Optical Potential
Ben Dahan, M., Peik, E., Reichel, J., Castin, Y., & Salomon, C. (1996) · Physical Review Letters · doi:10.1103/physrevlett.76.4508 · Cited by 958
Measurement of gravitational acceleration by dropping atoms
Peters, A., Chung, K. Y., & Chu, S. (1999) · Nature · doi:10.1038/23655 · Cited by 925 · cited 2×
“Even when we include the first-order correction [38,39] for the nonvanishing pulse duration τ assuming box-shaped pulses, the total phase shift [40] φtot 1⁄4 ðkeffg − 2παÞðT2 þ 3TτÞ vanishes independently of T and τ for the special case of α 1⁄4 keffg=ð2πÞ, where the atom number in one output port of the MZI assumes a…”
MethodAtom-chip-based generation of entanglement for quantum metrology
Riedel, M. F., Böhi, P., Li, Y., Hänsch, T. W., Sinatra, A., & Treutlein, P. (2010) · Nature · doi:10.1038/nature08988 · Cited by 874 · cited 1×
“Atom chips have already been employed very successfully in cold atom experiments [12–14], in particular for guided [15] or trapped [16] matter wave interferometry, microwave clocks [17,18] and magnetometry [15,19].”
MethodBose–Einstein condensation on a microelectronic chip
Hänsel, W., Hommelhoff, P., Hänsch, T. W., & Reichel, J. (2001) · Nature · doi:10.1038/35097032 · Cited by 662
Microscopic Atom Optics: From Wires to an Atom Chip
Folman, R., Krüger, P., Schmiedmayer, J., Denschlag, J., & Henkel, C. (2002) · Advances In Atomic, Molecular, and Optical Physics · doi:10.1016/s1049-250x(02)80011-8 · Cited by 658
Chemical mechanical planarization for microelectronics applications
Zantye, P. B., Kumar, A., & Sikder, A. K. (2004) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2004.06.002 · Cited by 635
Sensitive absolute-gravity gradiometry using atom interferometry
McGuirk, J. M., Foster, G. T., Fixler, J. B., Snadden, M. J., & Kasevich, M. A. (2002) · Physical Review A · doi:10.1103/physreva.65.033608 · Cited by 586 · cited 1×
“The frequency difference of the lasers can be adjusted such that there is either a momentum transfer in the up- or downward direction [10,34], which allows us to suppress the effect of recoil-dependent shifts on the interferometer phase with alternating momentum transfer [35,36].”
BackgroundMagnetic microtraps for ultracold atoms
Fortágh, J., & Zimmermann, C. (2007) · Reviews of Modern Physics · doi:10.1103/revmodphys.79.235 · Cited by 579
Cited by
The potential and global outlook of integrated photonics for quantum technologies
Pelucchi, E., Fagas, G., Aharonovich, I., Englund, D., Figueroa, E., Gong, Q., Hannes, H., Liu, J., Lu, C.-Y., Matsuda, N., et al. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00398-z · Cited by 533
Taking atom interferometric quantum sensors from the laboratory to real-world applications
Bongs, K., Holynski, M., Vovrosh, J., Bouyer, P., Condon, G., Rasel, E., Schubert, C., Schleich, W. P., & Roura, A. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0117-4 · Cited by 382
Self-citationExploring gravity with the MIGA large scale atom interferometer
Canuel, B., Bertoldi, A., Amand, L., Pozzo di Borgo, E., Chantrait, T., Danquigny, C., Dovale Álvarez, M., Fang, B., Freise, A., Geiger, R., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-32165-z · Cited by 285
Metadata
- Authors
- Abend, S., Gebbe, M., Gersemann, M., Ahlers, H., Müntinga, H., Giese, E., Gaaloul, N., Schubert, C., Lämmerzahl, C., Ertmer, W., Schleich, W. P., & Rasel, E. M.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2016-11-11
- Volume
- 117
- Issue
- 20
- Pages
- 203003-203003
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2553141772
- Cited by
- 180
- References
- 56
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atom-Chip Fountain Gravimeter. https://app.cochat.ai/papers/10.1103/physrevlett.117.203003
- The paper
- Abend, S., Gebbe, M., Gersemann, M., Ahlers, H., Müntinga, H., Giese, E., Gaaloul, N., Schubert, C., Lämmerzahl, C., Ertmer, W., Schleich, W. P., & Rasel, E. M. (2016). Atom-Chip Fountain Gravimeter. Physical Review Letters. https://doi.org/10.1103/physrevlett.117.203003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.