The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Precision measurement beyond the shot-noise limit
Abstract
An improvement in precision beyond the limit set by the vacuum-state or zero-point fluctuations of the electromagnetic field is reported for the measurement of phase modulation in an optical interferometer. The experiment makes use of squeezed light to reduce the level of fluctuations below the shot-noise limit. An increase in the signal-to-noise ratio of 3.0 dB relative to the shot-noise limit is demonstrated, with the improvement currently limited by losses in propagation and detection and not by the degree of available squeezing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Two-photon coherent states of the radiation field
Yuen, H. P. (1976) · Physical Review A · doi:10.1103/physreva.13.2226 · Cited by 2,074
Walls, D. F. (1983) · Nature · doi:10.1038/306141a0 · Cited by 1,934
Generation of Squeezed States by Parametric Down Conversion
Wu, L.-A., Kimble, H. J., Hall, J. L., & Wu, H. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.2520 · Cited by 1,653
Self-citationSqueezing of intracavity and traveling-wave light fields produced in parametric amplification
Collett, M. J., & Gardiner, C. W. (1984) · Physical Review A · doi:10.1103/physreva.30.1386 · Cited by 1,071
Quantum Nondemolition Measurements
Braginsky, V. B., Vorontsov, Y. I., & Thorne, K. S. (1980) · Science · doi:10.1126/science.209.4456.547 · Cited by 794
Yuen, H., & Shapiro, J. (1978) · IEEE Transactions on Information Theory · doi:10.1109/tit.1978.1055958 · Cited by 491
Quantum limits on resonant-mass gravitational-radiation detectors
Hollenhorst, J. N. (1979) · Physical Review D · doi:10.1103/physrevd.19.1669 · Cited by 339
Squeezed states in phase-sensing interferometers
Bondurant, R. S., & Shapiro, J. H. (1984) · Physical Review D · doi:10.1103/physrevd.30.2548 · Cited by 298
A multimode quantum theory of a degenerate parametric amplifier in a cavity
Gardiner, C. W., & Savage, C. M. (1984) · Optics Communications · doi:10.1016/0030-4018(84)90342-0 · Cited by 118
Cited by
Quantum-Enhanced Measurements: Beating the Standard Quantum Limit
Giovannetti, V., Lloyd, S., & Maccone, L. (2004) · Science · doi:10.1126/science.1104149 · Cited by 3,038
Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light
Aasi, J., Abadie, J., Abbott, B. P., Abbott, R., Abbott, T. D., Abernathy, M. R., Adams, C., Adams, T., Addesso, P., Adhikari, R. X., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.177 · Cited by 1,204
Optimal frequency measurements with maximally correlated states
Bollinger, J. J., Itano, W. M., Wineland, D. J., & Heinzen, D. J. (1996) · Physical Review A · doi:10.1103/physreva.54.r4649 · Cited by 1,167
Squeezed atomic states and projection noise in spectroscopy
Wineland, D. J., Bollinger, J. J., Itano, W. M., & Heinzen, D. J. (1994) · Physical Review A · doi:10.1103/physreva.50.67 · Cited by 1,166
Spin squeezing and reduced quantum noise in spectroscopy
Wineland, D. J., Bollinger, J. J., Itano, W. M., Moore, F. L., & Heinzen, D. J. (1992) · Physical Review A · doi:10.1103/physreva.46.r6797 · Cited by 1,135
Metadata
- Authors
- Xiao, M., Wu, L.-A., & Kimble, H. J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1987-07-20
- Volume
- 59
- Issue
- 3
- Pages
- 278-281
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W1970782469
- Cited by
- 723
- References
- 10
- FWCI
- 23.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.