The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Imaging Xe with a low-temperature scanning tunneling microscope
Abstract
We have obtained images of individual Xe atoms adsorbed on a Ni(110) surface using a low-temperature scanning tunneling microscope (STM). The atom-on-jellium model has been used to calculate the apparent height of a Xe atom as imaged with the STM and the result is found to be in good agreement with experiment. We conclude that the Xe 6s resonance, although lying close to the vacuum level, is the origin of the Fermi-level local state density which renders Xe ``visible'' in the STM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Theory of the scanning tunneling microscope
Tersoff, J., & Hamann, D. R. (1985) · Physical Review B · doi:10.1103/physrevb.31.805 · Cited by 4,411
Herman, F., Skillman, S., & Arents, J. (1964) · Journal of The Electrochemical Society · doi:10.1149/1.2426131 · Cited by 3,993
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Self-citationTheory and Application for the Scanning Tunneling Microscope
Tersoff, J., & Hamann, D. R. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.1998 · Cited by 2,554
Theory of atomic chemisorption on simple metals
Lang, N. D., & Williams, A. R. (1978) · Physical Review B · doi:10.1103/physrevb.18.616 · Cited by 565
Self-citation
Cited by
Confinement of Electrons to Quantum Corrals on a Metal Surface
Crommie, M. F., Lutz, C. P., & Eigler, D. M. (1993) · Science · doi:10.1126/science.262.5131.218 · Cited by 1,690
Self-citationAn atomic switch realized with the scanning tunnelling microscope
Eigler, D. M., Lutz, C. P., & Rudge, W. E. (1991) · Nature · doi:10.1038/352600a0 · Cited by 785
Self-citationStep and island dynamics at solid/vacuum and solid/liquid interfaces
Giesen, M. (2001) · Progress in Surface Science · doi:10.1016/s0079-6816(00)00021-6 · Cited by 439
Scanning Tunneling Microscopy and Atomic Force Microscopy in Organic Chemistry
Frommer, J. (1992) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199212981 · Cited by 383
Electron Transfer through Organic Molecules
Bumm, L. A., Arnold, J. J., Dunbar, T. D., Allara, D. L., & Weiss, P. S. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp9921699 · Cited by 366
Self-citation
Metadata
- Authors
- Eigler, D. M., Weiss, P. S., Schweizer, E. K., & Lang, N. D.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1991-03-04
- Volume
- 66
- Issue
- 9
- Pages
- 1189-1192
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2036246466
- Cited by
- 274
- References
- 5
- FWCI
- 16.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging Xe with a low-temperature scanning tunneling microscope. https://app.cochat.ai/papers/10.1103/physrevlett.66.1189
- The paper
- Eigler, D. M., Weiss, P. S., Schweizer, E. K., & Lang, N. D. (1991). Imaging Xe with a low-temperature scanning tunneling microscope. Physical Review Letters. https://doi.org/10.1103/physrevlett.66.1189
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.