The DOI matches its Crossref record.
Coherent phonon detection from ultrafast surface vibrations
Abstract
Using an optical technique ultrafast vibrations of the surface of thin opaque films in the 0.1-THz range have been directly observed in the time domain. We propose a new type of phonon detection by monitoring the surface velocity, and demonstrate an exceptional sensitivity to atomic-scale inhomogeneities by observing an anomalous reflection from a buried film of monolayer order in thickness.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
With the advancement of pico- and femtosecond pulsed lasers after 1980, the technique has been widely used for studying non-equilibrium electron-phonon interaction, detecting coherent phonon transport, and thermal transport across interfaces.
“With the advancement of pico-and femtosecond pulsed laser after 1980, this technique has been widely used for studying non-equilibrium electron-phonon interaction [89,90], detecting coherent phonon transport [91][92][93] and thermal transport across interfaces [94][95][96] .”
From Measurement Techniques for Thermal Conductivity and Interfacial Thermal Conductance of Bulk and Thin Film Materials (2016) · cites this paper as [90]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 21
- W. E. Bron, 1980, Rep. Prog. Phys., 43, 301, 10.1088/0034-4885/43/3/002 · DOI
- M. N. Wybourne, 1988, Rep. Prog. Phys., 51, 923, 10.1088/0034-4885/51/7/001 · DOI
- C. Thomsen, 1986, Phys. Rev. B, 34, 4129, 10.1103/PhysRevB.34.4129 · DOI
- C. Thomsen, 1986, Opt. Commun., 60, 55, 10.1016/0030-4018(86)90116-1 · DOI
- G. L. Eesley, 1987, Appl. Phys. Lett., 50, 717, 10.1063/1.98077 · DOI
- G. C. Cho, 1990, Phys. Rev. Lett., 65, 764, 10.1103/PhysRevLett.65.764 · DOI
- K. P. Cheung, 1985, Phys. Rev. Lett., 55, 2152, 10.1103/PhysRevLett.55.2152 · DOI
- J. J. Kasinski, 1988, Opt. Lett., 13, 710, 10.1364/OL.13.000710 · DOI
- J. E. Rothenberg, 1988, Opt. Lett., 13, 713, 10.1364/OL.13.000713 · DOI
- O. B. Wright, 1992, J. Appl. Phys., 71, 1617, 10.1063/1.351218 · DOI
- O. B. Wright, 1991, Opt. Lett., 16, 1529, 10.1364/OL.16.001529 · DOI
- J. Opsal, 1983, Appl. Opt., 22, 3169, 10.1364/AO.22.003169 · DOI
- J. A. Bell, 1988, Appl. Phys. Lett., 52, 610, 10.1063/1.99380 · DOI
- M. I. Kaganov, 1957, Sov. Phys. JETP, 4, 173
- S. I. Anisimov, 1975, Sov. Phys. JETP, 39, 375
- C. A. Paddock, 1986, J. Appl. Phys., 60, 285, 10.1063/1.337642 · DOI
- T. H. Zhu, 1991, Phys. Rev. B, 44, 4281, 10.1103/PhysRevB.44.4281 · DOI
- M. Cardona, 1969, Modulation Spectroscopy
- B. V. Paranjape, 1987, J. Appl. Phys., 61, 888, 10.1063/1.338139 · DOI
- E. T. Swartz, 1989, Rev. Mod. Phys., 61, 605, 10.1103/RevModPhys.61.605 · DOI
- B. M. Clemens, 1988, Phys. Rev. Lett., 61, 2356, 10.1103/PhysRevLett.61.2356 · DOI
Cited by
Sorted by citations
Zhao, D., Qian, X., Gu, X., Jajja, S. A., & Yang, R. (2016) · Journal of Electronic Packaging · doi:10.1115/1.4034605 · Cited by 559
Jiang, P., Qian, X., & Yang, R. (2018) · Journal of Applied Physics · doi:10.1063/1.5046944 · Cited by 424
Metadata
- Authors
- Wright, O. B., & Kawashima, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1992-09-14
- Volume
- 69
- Issue
- 11
- Pages
- 1668-1671
- ISSN
- 0031-9007
- Cited by
- 180
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review