New experimental limits to the time variations ofgp(me/mp) and α
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new experimental limit to the possible time variation of the proton gyromagnetic ratio times the electron-to-proton mass ratio has been obtained from the frequency comparison data between Cs and Mg atomic beam standards. The measurements, made over a period of one year, lead to an upper limit for the rate of change of ${\mathit{g}}_{\mathit{p}}$(${\mathit{m}}_{\mathit{e}}$/${\mathit{m}}_{\mathit{p}}$) of 5.4\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}3}$/yr. This result, based only on the validity of the quantum mechanical theory of the atomic spectra, together with astrophysical data regarding analogous products of atomic fundamental constants, leads also to a new limit for the time stability of the fine structure constant \ensuremath{\alpha} (2.7\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}13}$/yr).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DIRAC, P. A. M. (1937) · Nature · doi:10.1038/139323a0 · Cited by 1,495
Direct test of the constancy of fundamental nuclear constants
SHLYAKHTER, A. I. (1976) · Nature · doi:10.1038/264340a0 · Cited by 269
Time Variation of the Charge of the Proton
Dyson, F. J. (1967) · Physical Review Letters · doi:10.1103/physrevlett.19.1291 · Cited by 76
Cited by
The Confrontation between General Relativity and Experiment
Will, C. M. (2014) · Living Reviews in Relativity · doi:10.12942/lrr-2014-4 · Cited by 3,996
The fundamental constants and their variation: observational and theoretical status
Uzan, J.-P. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.403 · Cited by 1,162
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Search for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Atomic Clocks and Variations of the Fine Structure Constant
Prestage, J. D., Tjoelker, R. L., & Maleki, L. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.3511 · Cited by 298
Metadata
- Authors
- Godone, A., Novero, C., Tavella, P., & Rahimullah, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1993-10-11
- Volume
- 71
- Issue
- 15
- Pages
- 2364-2366
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W1577223834
- Cited by
- 41
- References
- 3
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.