The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
First Phase-Coherent Frequency Measurement of Visible Radiation
Abstract
We have determined the frequency of the $^{3}P_{1}$- $^{1}S_{0}$ intercombination transition of atomic ${}^{40}\mathrm{Ca}$ stored in a magneto-optical trap to be $\ensuremath{\nu}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}455986240493.95\mathrm{kHz}$ with an estimated standard uncertainty of $0.43\mathrm{kHz}$ $(\ensuremath{\delta}\ensuremath{\nu}/\ensuremath{\nu}<{10}^{\ensuremath{-}12})$ using a phase-coherent optical frequency chain from the Cs atomic clock to the visible. This allows the realization of the SI-unit meter according to its definition by visible radiation with 25-fold reduced uncertainty compared to previous measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DIRAC, P. A. M. (1937) · Nature · doi:10.1038/139323a0 · Cited by 1,495
Cited by
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Optical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Metadata
- Authors
- Schnatz, H., Lipphardt, B., Helmcke, J., Riehle, F., & Zinner, G.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1996-01-01
- Volume
- 76
- Issue
- 1
- Pages
- 18-21
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2016259771
- Cited by
- 246
- References
- 1
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.