The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Abstract
We describe the formation and control of nanoscale, submerged fluid jets. The focusing process necessary to achieve these small length scales is characterized experimentally and theoretically. Fast mixing is one important application of nanoscale fluid control: We demonstrate this with a continuous-flow mixer capable of mix times of less than $10\ensuremath{\mu}\mathrm{s}$ and sample consumption rates of nanoliters per second. This new technique facilitates the study of fast reaction kinetics on time scales unattainable with conventional mixing technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An introduction to fluid dynamics
Curle, N. (1968) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(68)90038-0 · Cited by 6,135
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Chemical kinetics: The study of reaction rates in solution
Mozzon, M. (1991) · Inorganica Chimica Acta · doi:10.1016/s0020-1693(00)83080-7 · Cited by 603
Biotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523
Self-citationSubmillisecond protein folding kinetics studied by ultrarapid mixing
Chan, C.-K., Hu, Y., Takahashi, S., Rousseau, D. L., Eaton, W. A., & Hofrichter, J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.5.1779 · Cited by 248
Fast events in protein folding
Eaton, W. A., Thompson, P. A., Chan, C.-K., Hage, S. J., & Hofrichter, J. (1996) · Structure · doi:10.1016/s0969-2126(96)00121-9 · Cited by 117
Self-Sorting of White Blood Cells in a Lattice
Carlson, R. H., Gabel, C. V., Chan, S. S., et al. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2149 · Cited by 117
Parsons, R. (1992) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(92)80314-t · Cited by 57
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Metadata
- Authors
- Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1998-04-27
- Volume
- 80
- Issue
- 17
- Pages
- 3863-3866
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2059106681
- Cited by
- 887
- References
- 8
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.