The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Simultaneous Imaging of Individual Molecules Aligned Both Parallel and Perpendicular to the Optic Axis
Abstract
We report the first room temperature observation of an emission pattern from a single fluorescent molecule signifying that the emission dipole is aligned along the optic $(z)$ axis of a microscopic imaging system. This technique takes advantage of the $x$, $y$, and $z$-polarized evanescent fields generated in total internal reflection and the usually nettlesome aberrations commonly encountered when imaging biological samples with high numerical aperture oil-immersion objectives. For both $z$-oriented and transverse-oriented individual molecules of the carbocyanine dye ${\mathrm{DiIC}}_{18}$ embedded in polymethyl-methacrylate (PMMA), calculated images accurately model the main features of observed emission patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of single kinesin molecules moving along microtubules
Vale, R. D., Funatsu, T., Pierce, D. W., Romberg, L., Harada, Y., & Yanagida, T. (1996) · Nature · doi:10.1038/380451a0 · Cited by 711
Cited by
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959
Methods of single-molecule fluorescence spectroscopy and microscopy
Moerner, W. E., & Fromm, D. P. (2003) · Review of Scientific Instruments · doi:10.1063/1.1589587 · Cited by 881
Self-citationAdvances in Single-Molecule Fluorescence Methods for Molecular Biology
Joo, C., Balci, H., Ishitsuka, Y., Buranachai, C., & Ha, T. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.070606.101543 · Cited by 726
The Rylene Colorant Family—Tailored Nanoemitters for Photonics Research and Applications
Weil, T., Vosch, T., Hofkens, J., Peneva, K., & Müllen, K. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200902532 · Cited by 657
Three-dimensional structural dynamics of myosin V by single-molecule fluorescence polarization
Forkey, J. N., Quinlan, M. E., Alexander Shaw, M., Corrie, J. E. T., & Goldman, Y. E. (2003) · Nature · doi:10.1038/nature01529 · Cited by 455
Metadata
- Authors
- Dickson, R. M., Norris, D. J., & Moerner, W. E.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1998-12-14
- Volume
- 81
- Issue
- 24
- Pages
- 5322-5325
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1964329844
- Cited by
- 186
- References
- 1
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous Imaging of Individual Molecules Aligned Both Parallel and Perpendicular to the Optic Axis. https://app.cochat.ai/papers/10.1103/physrevlett.81.5322
- The paper
- Dickson, R. M., Norris, D. J., & Moerner, W. E. (1998). Simultaneous Imaging of Individual Molecules Aligned Both Parallel and Perpendicular to the Optic Axis. Physical Review Letters. https://doi.org/10.1103/physrevlett.81.5322
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.