The DOI matches its Crossref record.
Optical Frequency Measurement of the2S−12DTransitions in Hydrogen and Deuterium: Rydberg Constant and Lamb Shift Determinations
Abstract
We have performed a pure optical frequency measurement of the $2S\ensuremath{-}12D$ two-photon transitions in atomic hydrogen and deuterium. From a complete analysis taking into account this result and all other precise measurements (by ourselves and other authors), we deduce optimized values for the Rydberg constant, ${R}_{\ensuremath{\infty}}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}109737.31568516(84){\mathrm{cm}}^{\ensuremath{-}1}$ (relative uncertainty of $7.7\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$) and for the $1S$ and $2S$ Lamb shifts ${L}_{1S}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}8172.837(22)\mathrm{MHz}$ and ${L}_{2S\ensuremath{-}2P}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}1057.8446(29)\mathrm{MHz}$ [respectively, ${L}_{1S}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}8183.966(22)\mathrm{MHz}$, and ${L}_{2S\ensuremath{-}2P}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}1059.2337(29)\mathrm{MHz}$ for deuterium]. These are now the most accurate values available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Pohl, R., Antognini, A., Nez, F., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Fernandes, L. M. P., et al. (2010) · Nature · doi:10.1038/nature09250 · Cited by 1,374
Self-citationColloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Metadata
- Authors
- Schwob, C., Jozefowski, L., de Beauvoir, B., Hilico, L., Nez, F., Julien, L., Biraben, F., Acef, O., Zondy, J.-J., & Clairon, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-06-21
- Volume
- 82
- Issue
- 25
- Pages
- 4960-4963
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2025415824
- Cited by
- 232
- References
- 0
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical Frequency Measurement of the2S−12DTransitions in Hydrogen and Deuterium: Rydberg Constant and Lamb Shift Determinations. https://app.cochat.ai/papers/10.1103/physrevlett.82.4960
- The paper
- Schwob, C., Jozefowski, L., de Beauvoir, B., Hilico, L., Nez, F., Julien, L., Biraben, F., Acef, O., Zondy, J.-J., & Clairon, A. (1999). Optical Frequency Measurement of the2S−12DTransitions in Hydrogen and Deuterium: Rydberg Constant and Lamb Shift Determinations. Physical Review Letters. https://doi.org/10.1103/physrevlett.82.4960
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.