The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Cooling of a Mirror by Radiation Pressure
Open accessAbstract
We describe an experiment in which a mirror is cooled by the radiation pressure of light. A high-finesse optical cavity with a mirror coated on a mechanical resonator is used as an optomechanical sensor of the Brownian motion of the mirror. A feedback mechanism controls this motion via the radiation pressure of a laser beam reflected on the mirror. We have observed either a cooling or a heating of the mirror, depending on the gain of the feedback loop.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIGO: The Laser Interferometer Gravitational-Wave Observatory
Abramovici, A., Althouse, W. E., Drever, R. W. P., Gürsel, Y., Kawamura, S., Raab, F. J., Shoemaker, D., Sievers, L., Spero, R. E., Thorne, K. S., et al. (1992) · Science · doi:10.1126/science.256.5055.325 · Cited by 2,244
Thermal noise in mechanical experiments
Saulson, P. R. (1990) · Physical Review D · doi:10.1103/physrevd.42.2437 · Cited by 852
Mechanical parametric amplification and thermomechanical noise squeezing
Rugar, D., & Grütter, P. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.699 · Cited by 631
The VIRGO Project: A wide band antenna for gravitational wave detection
Bradaschia, C., Del Fabbro, R., Di Virgilio, A., Giazotto, A., Kautzky, H., Montelatici, V., Passuello, D., Brillet, A., Cregut, O., Hello, P., et al. (1990) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(90)91525-g · Cited by 491
Optical Bistability and Mirror Confinement Induced by Radiation Pressure
Dorsel, A., McCullen, J. D., Meystre, P., Vignes, E., & WALTHER, H. (1983) · Physical Review Letters · doi:10.1103/physrevlett.51.1550 · Cited by 430
Optomechanical Cooling of a Macroscopic Oscillator by Homodyne Feedback
Mancini, S., Vitali, D., & Tombesi, P. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.688 · Cited by 334
Regulation of a microcantilever response by force feedback
Mertz, J., Marti, O., & Mlynek, J. (1993) · Applied Physics Letters · doi:10.1063/1.109413 · Cited by 265
Tittonen, I. J., Breitenbach, G., Kalkbrenner, T., Müller, T., Conradt, R., Schiller, S., Steinsland, E., Blanc, N., & de Rooij, N. F. (1999) · Physical Review A · doi:10.1103/physreva.59.1038 · Cited by 145
High-sensitivity optical measurement of mechanical Brownian motion
Hadjar, Y., Cohadon, P.-F., Aminoff, C. G., Pinard, M., & Heidmann, A. (1999) · Europhysics Letters (EPL) · doi:10.1209/epl/i1999-00422-6 · Cited by 86
Self-citationSopczak, A. (1999) · The European Physical Journal C · doi:10.1007/pl00021666 · Cited by 84
High-sensitivity optical measurement of mechanical Brownian motion
Hadjar, Y., Cohadon, P.-F., Aminoff, C. G., Pinard, M., & Heidmann, A. (1999) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 57
Self-citation
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Quantum-Enhanced Measurements: Beating the Standard Quantum Limit
Giovannetti, V., Lloyd, S., & Maccone, L. (2004) · Science · doi:10.1126/science.1104149 · Cited by 3,038
Laser cooling of a nanomechanical oscillator into its quantum ground state
Chan, J., Alegre, T. P. M., Safavi-Naeini, A. H., Hill, J. T., Krause, A., Gröblacher, S., Aspelmeyer, M., & Painter, O. (2011) · Nature · doi:10.1038/nature10461 · Cited by 2,311
Cavity Optomechanics: Back-Action at the Mesoscale
Kippenberg, T. J., & Vahala, K. J. (2008) · Science · doi:10.1126/science.1156032 · Cited by 1,889
Quantum Theory of Cavity-Assisted Sideband Cooling of Mechanical Motion
Marquardt, F., Chen, J. P., Clerk, A. A., & Girvin, S. M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.093902 · Cited by 1,146
Metadata
- Authors
- Cohadon, P. F., Heidmann, A., & Pinard, M.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-10-18
- Volume
- 83
- Issue
- 16
- Pages
- 3174-3177
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1971072085
- Cited by
- 497
- References
- 11
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.