The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Regulation of a microcantilever response by force feedback
Abstract
A feedback mechanism is used to control the forces incident on a mechanical microcantilever as a function of the monitored cantilever motion. The control is effected by modifying the intensity of an auxiliary laser beam that generates a thermally induced stress. The feedback is designed to reduce the effective resonance quality factor of the cantilever. The resultant regulation of the cantilever motion is shown to improve the measurement dynamics in atomic force microscopy, without significantly degrading the signal to noise ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D. (1991) · Journal of Applied Physics · doi:10.1063/1.347347 · Cited by 2,434
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Mechanical parametric amplification and thermomechanical noise squeezing
Rugar, D., & Grütter, P. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.699 · Cited by 631
Magnetic force microscopy: General principles and application to longitudinal recording media
Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T. (1990) · Journal of Applied Physics · doi:10.1063/1.346713 · Cited by 624
Force microscopy with a bidirectional capacitance sensor
Neubauer, G., Cohen, S. R., McClelland, G. M., Horne, D., & Mate, C. M. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141354 · Cited by 188
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Towards quantum superpositions of a mirror
Marshall, W., Simon, C., Penrose, R., & Bouwmeester, D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.130401 · Cited by 960
Cavity cooling of a microlever
Metzger, C. H., & Karrai, K. (2004) · Nature · doi:10.1038/nature03118 · Cited by 677
Sub-kelvin optical cooling of a micromechanical resonator
Kleckner, D., & Bouwmeester, D. (2006) · Nature · doi:10.1038/nature05231 · Cited by 664
Phase-noise measurement in a cavity with a movable mirror undergoing quantum Brownian motion
Giovannetti, V., & Vitali, D. (2001) · Physical Review A · doi:10.1103/physreva.63.023812 · Cited by 515
Metadata
- Authors
- Mertz, J., Marti, O., & Mlynek, J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1993-05-10
- Volume
- 62
- Issue
- 19
- Pages
- 2344-2346
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1995571561
- Cited by
- 265
- References
- 6
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regulation of a microcantilever response by force feedback. https://app.cochat.ai/papers/10.1063/1.109413
- The paper
- Mertz, J., Marti, O., & Mlynek, J. (1993). Regulation of a microcantilever response by force feedback. Applied Physics Letters. https://doi.org/10.1063/1.109413
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.