The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Molecular Iodine Clock
Abstract
We demonstrate a simple optical clock based on an optical transition of iodine molecules, providing a frequency stability superior to most rf sources. Combined with a femtosecond-laser-based optical comb to provide the phase coherent clock mechanism linking the optical and microwave spectra, we derive an rf clock signal of comparable stability over an extended period. Measurements suggest the stability ( $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}$ at 1 s) of the cw laser locked on the iodine transition is transferred to every comb component throughout the optical octave bandwidth (from 532 to 1064 nm) with a precision of $3.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$. Characterization of the performance of the optical clock shows (in-)stability below $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$ at 1 s (currently limited by the microwave sources), and $4.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}$ over one year.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Self-citationNiering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationColloquium: Femtosecond optical frequency combs
Cundiff, S. T., & Ye, J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.325 · Cited by 1,083
Self-citation20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Direct frequency comb spectroscopy in the extreme ultraviolet
Cingöz, A., Yost, D. C., Allison, T. K., Ruehl, A., Fermann, M. E., Hartl, I., & Ye, J. (2012) · Nature · doi:10.1038/nature10711 · Cited by 477
Self-citationQuinn, T. J. (2003) · Metrologia · doi:10.1088/0026-1394/40/2/316 · Cited by 409
Metadata
- Authors
- Ye, J., Ma, L. S., & Hall, J. L.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2001-12-13
- Volume
- 87
- Issue
- 27
- Pages
- 270801-270801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2037728196
- Cited by
- 206
- References
- 2
- FWCI
- 12.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular Iodine Clock. https://app.cochat.ai/papers/10.1103/physrevlett.87.270801
- The paper
- Ye, J., Ma, L. S., & Hall, J. L. (2001). Molecular Iodine Clock. Physical Review Letters. https://doi.org/10.1103/physrevlett.87.270801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.