The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.7 ppm
Open accessAbstract
A higher precision measurement of the anomalous $g$ value, ${a}_{\ensuremath{\mu}}=(g\ensuremath{-}2)/2$, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data collected in the year 2000. The result ${a}_{{\ensuremath{\mu}}^{+}}=11\text{ }659\text{ }204(7)(5)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$ (0.7 ppm) is in good agreement with previous measurements and has an error about one-half that of the combined previous data. The present world average experimental value is ${a}_{\ensuremath{\mu}}(\mathrm{e}\mathrm{x}\mathrm{p}\mathrm{t})=11\text{ }659\text{ }203(8)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}10}$ (0.7 ppm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
Precise Measurement of the Positive Muon Anomalous Magnetic Moment
Brown, H. N., Bunce, G., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deile, M., Deng, H., Deninger, W., Dhawan, S. K., et al. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.2227 · Cited by 533
Self-citationMuon anomalous magnetic moment: A harbinger for “new physics”
Czarnecki, A., & Marciano, W. J. (2001) · Physical Review D · doi:10.1103/physrevd.64.013014 · Cited by 433
Bailey, J., Borer, K., Combley, F., Drumm, H., Eck, C., Farley, F. J. M., Field, J. H., Flegel, W., Hattersley, P. M., Krienen, F., et al. (1979) · Nuclear Physics B · doi:10.1016/0550-3213(79)90292-x · Cited by 428
Self-citationHadronic light-by-light corrections to the muong−2:The pion-pole contribution
Knecht, M., & Nyffeler, A. (2002) · Physical Review D · doi:10.1103/physrevd.65.073034 · Cited by 346
Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., et al. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.711 · Cited by 292
Self-citationHadronic Light-By-Light Scattering Contribution to the Muong−2: An Effective Field Theory Approach
Knecht, M., Nyffeler, A., Perrottet, M., & de Rafael, E. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.071802 · Cited by 239
Comment on the pion pole part of the light-by-light contribution to the muon g−2
Bijnens, J., Pallante, E., & Joaquim Prades, B. (2002) · Nuclear Physics B · doi:10.1016/s0550-3213(02)00074-3 · Cited by 228
Measurement of e+e−→π+π− cross-section with CMD-2 around ρ-meson
Akhmetshin, R. R., Anashkin, E. V., Arbuzov, A. B., Aulchenko, V. M., Banzarov, V. S., Barkov, L. M., Baru, S. E., Bashtovoy, N. S., Bondar, A. E., Bondarev, D. V., et al. (2002) · Physics Letters B · doi:10.1016/s0370-2693(02)01168-1 · Cited by 193
Self-citationHigher-order hadronic contributions to the anomalous magnetic moment of leptons
Krause, B. (1997) · Physics Letters B · doi:10.1016/s0370-2693(96)01346-9 · Cited by 185
Pion Pole Contribution to Hadronic Light-By-Light Scattering and Muon Anomalous Magnetic Moment
Blokland, I., Czarnecki, A., & Kirill Melnikov, B. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.071803 · Cited by 163
Precision determination of the pion form factor and calculation of the muon g−2
de Trocóniz, J. F., & Ynduráin, F. (2002) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.65.093001 · Cited by 113
A high precision magnetometer based on pulsed NMR
Prigl, R., Haeberlen, U., Jungmann, K. P., PUTLITZ, G. Z., & von Walter, P. (1996) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/0168-9002(96)37493-7 · Cited by 98
Self-citationNew Measurement of the Anomalous Magnetic Moment of the Positive Muon
Carey, R. M., Earle, W., Efstathiadis, E., Hare, M. F., Hazen, E. S., Hughes, B. J., Krienen, F., Miller, J. P., Monich, V., Ouyang, J., et al. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.1632 · Cited by 97
Self-citationMuon and tau anomalies updated
Stephan Narison, A. (2001) · Physics Letters B · doi:10.1016/s0370-2693(01)00743-2 · Cited by 88
Improved measurement of the positive muon anomalous magnetic moment
Brown, H., Bunce, G. M., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deng, H., Deninger, W. J., Dhawan, S., Дружинин, В. П., et al. (2000) · Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields · doi:10.1103/physrevd.62.091101 · Cited by 82
Self-citationPrecision measurement of the magnetic field in terms of the free-proton NMR frequency
Fei, X., Hughes, V. W., & Prigl, R. (1997) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(97)84161-7 · Cited by 76
Self-citationThe Brookhaven muon storage ring magnet
Danby, G. T., Addessi, L., Armoza, Z., Benante, J., Brown, H., Bunce, G. M., Cottingham, J., Cullen, J., Geller, J., Hseuh, H. C., et al. (2001) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(00)00704-x · Cited by 62
Self-citationElectromagnetic calorimeters for the BNL muon (g−2) experiment
Sedykh, S., Blackburn, J., Bunker, B., Debevec, P. T., Gray, F., Hertzog, D. W., Jones, T. D., Onderwater, C. J. G., Polly, C. C., Urner, D., et al. (2000) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(00)00576-3 · Cited by 43
Self-citation
Cited by
Particle dark matter: evidence, candidates and constraints
Bertone, G., Hooper, D., & Silk, J. (2005) · Physics Reports · doi:10.1016/j.physrep.2004.08.031 · Cited by 4,979
Final report of the E821 muon anomalous magnetic moment measurement at BNL
Bennett, G. W., Bousquet, B., Brown, H. N., Bunce, G., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deile, M., Deng, H., et al. (2006) · Physical Review D · doi:10.1103/physrevd.73.072003 · Cited by 2,451
Self-citationJegerlehner, F., & Nyffeler, A. (2009) · Physics Reports · doi:10.1016/j.physrep.2009.04.003 · Cited by 1,103
R-Parity-violating supersymmetry
Barbier, R., Bérat, C., Besançon, M., Chemtob, M., Deandrea, A., Dudas, E., Fayet, P., Lavignac, S., Moreau, G., Perez, E., et al. (2005) · Physics Reports · doi:10.1016/j.physrep.2005.08.006 · Cited by 1,043
Measurement of the Negative Muon Anomalous Magnetic Moment to 0.7 ppm
Bennett, G. W., Bousquet, B., Brown, H. N., Bunce, G., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deile, M., Deng, H., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.161802 · Cited by 855
Self-citation
Metadata
- Authors
- Bennett, G. W., Bousquet, B., Brown, H. N., Bunce, G., Carey, R. M., Cushman, P., Danby, G. T., Debevec, P. T., Deile, M., Deng, H., Deninger, W., Dhawan, S. K., Druzhinin, V. P., Duong, L., Efstathiadis, E., Farley, F. J. M., Fedotovich, G. V., Giron, S., Gray, F. E., Grigoriev, D., Grosse-Perdekamp, M., Grossmann, A., Hare, M. F., Hertzog, D. W., Huang, X., Hughes, V. W., Iwasaki, M., Jungmann, K., Kawall, D., Khazin, B. I., Kindem, J., Krienen, F., Kronkvist, I., Lam, A., Larsen, R., Lee, Y. Y., Logashenko, I., McNabb, R., Meng, W., Mi, J., Miller, J. P., Morse, W. M., Nikas, D., Onderwater, C. J. G., Orlov, Y., Özben, C. S., Paley, J. M., Peng, Q., Polly, C. C., Pretz, J., Prigl, R., zu Putlitz, G., Qian, T., Redin, S. I., Rind, O., Roberts, B. L., Ryskulov, N., Shagin, P., Semertzidis, Y. K., Shatunov, Y. M., Sichtermann, E. P., Solodov, E., Sossong, M., Steinmetz, A., Sulak, L. R., Trofimov, A., Urner, D., von Walter, P., Warburton, D., & Yamamoto, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2002-08-20
- Volume
- 89
- Issue
- 10
- Pages
- 101804-101804
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W4232925476
- Cited by
- 395
- References
- 19
- FWCI
- 37.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.