The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Guiding of High-Intensity Laser Pulses with a Hydrogen-Filled Capillary Discharge Waveguide
Abstract
We report guiding of laser pulses with peak input intensities greater than ${10}^{17}\text{ }\mathrm{W}\text{ }\mathrm{c}{\mathrm{m}}^{\mathrm{\ensuremath{-}}\mathrm{2}}$ in 30 mm and 50 mm long ${\mathrm{H}}_{\mathrm{2}}$-filled capillary discharge waveguides. Under conditions producing good guiding the coupling and propagation losses of the waveguide were $<4%$ and $(7\ifmmode\pm\else\textpm\fi{}1)\text{ }{\mathrm{m}}^{\mathrm{\ensuremath{-}}\mathrm{1}}$, respectively. The spectra of the transmitted pulses were not broadened significantly, but were shifted to shorter wavelength. It is concluded that this shift is not associated with significant temporal distortion of the laser pulse.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light pipe for high intensity laser pulses
Durfee, C. G., & Milchberg, H. M. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.2409 · Cited by 517
Cited by
Physics of laser-driven plasma-based electron accelerators
Esarey, E., Schroeder, C. B., & Leemans, W. P. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1229 · Cited by 2,550
GeV electron beams from a centimetre-scale accelerator
Leemans, W. P., Nagler, B., Gonsalves, A. J., Tóth, C., Nakamura, K., Geddes, C. G. R., Esarey, E., Schroeder, C. B., & Hooker, S. M. (2006) · Nature Physics · doi:10.1038/nphys418 · Cited by 1,708
Self-citationLeemans, W. P., Gonsalves, A. J., Mao, H.-S., Nakamura, K., Benedetti, C., Schroeder, C. B., Tóth, C., Daniels, J., Mittelberger, D. E., Bulanov, S. S., et al. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.245002 · Cited by 923
Quasi-monoenergetic laser-plasma acceleration of electrons to 2 GeV
Wang, X., Zgadzaj, R., Fazel, N., Li, Z., Yi, S. A., Zhang, X., Henderson, W., Chang, Y.-Y., Korzekwa, R., Tsai, H.-E., et al. (2013) · Nature Communications · doi:10.1038/ncomms2988 · Cited by 642
Developments in laser-driven plasma accelerators
Hooker, S. M. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.234 · Cited by 345
Self-citation
Metadata
- Authors
- Butler, A., Spence, D. J., & Hooker, S. M.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2002-10-14
- Volume
- 89
- Issue
- 18
- Pages
- 185003-185003
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1998185698
- Cited by
- 250
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guiding of High-Intensity Laser Pulses with a Hydrogen-Filled Capillary Discharge Waveguide. https://app.cochat.ai/papers/10.1103/physrevlett.89.185003
- The paper
- Butler, A., Spence, D. J., & Hooker, S. M. (2002). Guiding of High-Intensity Laser Pulses with a Hydrogen-Filled Capillary Discharge Waveguide. Physical Review Letters. https://doi.org/10.1103/physrevlett.89.185003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.