The DOI matches its Crossref record.
A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers
Abstract
It is one of the basic concepts of Newtonian fluid dynamics that at low Reynolds number (Re) the Navier-Stokes equation is linear and flows are reversible. In microfluidic devices, where Re is essentially always low, this implies that flow resistance in microchannels is isotropic. Here we present a microfluidic rectifier: a microscopic channel of a special shape whose flow resistance is strongly anisotropic, differing by up to a factor of 2 for opposite flow directions. Its nonlinear operation at arbitrary small Re is due to non-Newtonian elastic properties of the working fluid, which is a 0.01% aqueous solution of a high molecular weight polymer. The rectifier works as a dynamic valve and may find applications in microfluidic pumps and other integrated devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Directing cell motions on micropatterned ratchets
Mahmud, G., Campbell, C. J., Bishop, K. J. M., Komarova, Y. A., Chaga, O., Soh, S., Huda, S., Kandere-Grzybowska, K., & Grzybowski, B. A. (2009) · Nature Physics · doi:10.1038/nphys1306 · Cited by 329
Yang, B., Kong, J., & Fang, X. (2019) · Talanta · doi:10.1016/j.talanta.2019.06.031 · Cited by 83
Metadata
- Authors
- Groisman, A., & Quake, S. R.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2004-03-04
- Volume
- 92
- Issue
- 9
- Pages
- 094501-094501
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2028404626
- Cited by
- 202
- References
- 0
- FWCI
- 5.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers. https://app.cochat.ai/papers/10.1103/physrevlett.92.094501
- The paper
- Groisman, A., & Quake, S. R. (2004). A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers. Physical Review Letters. https://doi.org/10.1103/physrevlett.92.094501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.