Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record.

A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers

Groisman, Alex, Quake, Stephen R.·2004·Physical Review Letters

Abstract

It is one of the basic concepts of Newtonian fluid dynamics that at low Reynolds number (Re) the Navier-Stokes equation is linear and flows are reversible. In microfluidic devices, where Re is essentially always low, this implies that flow resistance in microchannels is isotropic. Here we present a microfluidic rectifier: a microscopic channel of a special shape whose flow resistance is strongly anisotropic, differing by up to a factor of 2 for opposite flow directions. Its nonlinear operation at arbitrary small Re is due to non-Newtonian elastic properties of the working fluid, which is a 0.01% aqueous solution of a high molecular weight polymer. The rectifier works as a dynamic valve and may find applications in microfluidic pumps and other integrated devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.92.094501

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Groisman, A., & Quake, S. R.
Venue
Physical Review Letters
Published
2004-03-04
Volume
92
Issue
9
Pages
094501-094501
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2028404626
Cited by
202
References
0
FWCI
5.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers. https://app.cochat.ai/papers/10.1103/physrevlett.92.094501
The paper
Groisman, A., & Quake, S. R. (2004). A Microfluidic Rectifier: Anisotropic Flow Resistance at Low Reynolds Numbers. Physical Review Letters. https://doi.org/10.1103/physrevlett.92.094501

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.