Lifetime Measurement of theP23Metastable State of Strontium Atoms
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have measured the lifetime of the 5s5p 3P2 metastable state of strontium atoms by magneto-optically trapping the decayed atoms to the ground state, which allowed sensitive detection of the rare decay events. We found that the blackbody radiation-induced decay was the dominant decay channel for the state at T=300 K. The lifetime was determined to be 520(+310)(-140) s in the limit of zero temperature, arguably the longest lifetime ever determined in a laboratory environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Demonstration of a Fundamental Quantum Logic Gate
Monroe, C., Meekhof, D. M., King, B. E., Itano, W. M., & Wineland, D. J. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.4714 · Cited by 1,586
Shelved optical electron amplifier: Observation of quantum jumps
Nagourney, W., Sandberg, J., & Dehmelt, H. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.2797 · Cited by 937
Cited by
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
“1(2) s after correcting for BBR-induced decay [33].”
BackgroundDeSalvo, B. J., Yan, M., Mickelson, P. G., Martinez de Escobar, Y. N., & Killian, T. C. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.030402 · Cited by 217
Lattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Muniz, J. A., Young, D. J., Cline, J. R. K., & Thompson, J. K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023152 · Cited by 38
Metadata
- Authors
- Yasuda, M., & Katori, H.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2004-04-15
- Volume
- 92
- Issue
- 15
- Pages
- 153004-153004
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1971071591
- Cited by
- 74
- References
- 2
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lifetime Measurement of theP23Metastable State of Strontium Atoms. https://app.cochat.ai/papers/10.1103/physrevlett.92.153004
- The paper
- Yasuda, M., & Katori, H. (2004). Lifetime Measurement of theP23Metastable State of Strontium Atoms. Physical Review Letters. https://doi.org/10.1103/physrevlett.92.153004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.