An optical lattice clock with accuracy and stability at the 10−18 level
Open accessAbstract
Progress in atomic, optical and quantum science has led to rapid improvements in atomic clocks. At the same time, atomic clock research has helped to advance the frontiers of science, affecting both fundamental and applied research. The ability to control quantum states of individual atoms and photons is central to quantum information science and precision measurement, and optical clocks based on single ions have achieved the lowest systematic uncertainty of any frequency standard. Although many-atom lattice clocks have shown advantages in measurement precision over trapped-ion clocks, their accuracy has remained 16 times worse. Here we demonstrate a many-atom system that achieves an accuracy of 6.4 × 10(-18), which is not only better than a single-ion-based clock, but also reduces the required measurement time by two orders of magnitude. By systematically evaluating all known sources of uncertainty, including in situ monitoring of the blackbody radiation environment, we improve the accuracy of optical lattice clocks by a factor of 22. This single clock has simultaneously achieved the best known performance in the key characteristics necessary for consideration as a primary standard-stability and accuracy. More stable and accurate atomic clocks will benefit a wide range of fields, such as the realization and distribution of SI units, the search for time variation of fundamental constants, clock-based geodesy and other precision tests of the fundamental laws of nature. This work also connects to the development of quantum sensors and many-body quantum state engineering (such as spin squeezing) to advance measurement precision beyond the standard quantum limit.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Bloom et al. (2014) demonstrated an atomic clock with a many-atom system that reaches an accuracy of 6×10^-18 and could improve the accuracy of optical lattice clocks by a factor of 22.
“Bloom et al. (2014) demonstrated an atomic clock with a many-atom system that reaches an accuracy of 6×10 -18 and could improve the accuracy of optical lattice clocks by a factor of 22.”
From Time transfer and significance of vertical land motion in relativistic geodesy applications: a review paper (2023) · cites this paper as Bloom et al. (2014)
The Abstract (p. 1) says the many-atom clock achieves an accuracy of 6×10^-18. The Introduction (p. 2) reports a factor-of-20 improvement in total uncertainty over earlier optical lattice clocks, not the claimed factor of 22. (LLM, conf=0.88)
Experimental — accuracy not yet measuredOptical clocks operate at frequencies about five orders of magnitude higher than caesium clocks and thus achieve higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10^18.
“The optical clocks operate at frequencies about five orders of magnitude higher than the caesium clocks and thus achieve a higher frequency stability, approaching fractional stabilities and uncertainties of one part in 10 18 (Chou et al. 2010;Hinkley et al. 2013;Bloom et al. 2014;Nicholson et al. 2015;Ushijima et al. 2015;Huntemann et al. 2016).”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Bloom et al. 2014
The Introduction (pp. 2–3) reports a fractional uncertainty of 6.4×10⁻¹⁸ and an instability of 3×10⁻¹⁸ at 10,000 seconds, supporting the claim that optical clocks approach the 10⁻¹⁸ level. It does not state that their operating frequencies are about five orders of magnitude above caesium clocks or attribute their higher stability to that frequency difference. (LLM, conf=0.86)
Experimental — accuracy not yet measuredThe latest generation of optical clocks and dedicated frequency links are approaching to deliver comparison of frequencies at the level of 1.0 × 10−18.
“The latest generation of optical clocks as well as the dedicated frequency links, for example optical fibres, are now approaching to deliver the comparison of frequencies at the level of 1.0 × 10−18.”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Bloom et al. 2014
The Introduction (p. 2) reports an optical clock uncertainty of 6.4 × 10−18, and the Conclusions (p. 9) say the demonstrated techniques have no foreseeable limitation to reaching below 1 × 10−18. The Introduction also discusses advances in frequency distribution, with a fibre-link study listed in the References (p. 10). But the paper does not establish a clock comparison over a dedicated link at 1 × 10−18; its reported comparison of two clocks had a combined uncertainty of 5.4 × 10−17 (Frequency Comparison, p. 3). (LLM, conf=0.82)
Experimental — accuracy not yet measuredThe frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching one part in 10^18.
“The frequency stability and uncertainty of the latest generation of optical atomic clocks is now approaching the one part in 10 18 level.”
From Geodetic methods to determine the relativistic redshift at the level of 10 $$^{-18}$$ - 18 in the context of international timescales: a review and practical results (2018) · cites this paper as Bloom et al. 2014
Recently, two optical clocks in laboratories approached the 10−18 level.
“Recently, two optical clocks in laboratories approached the 10−18 level (Bloom et al. 2014; Huntemann et al. 2016).”
From Clock networks for height system unification: a simulation study (2019) · cites this paper as Bloom et al. 2014
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Part of this paper’s reference list could not be split into single entries.
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · see citing works
Takamoto, M., Hong, F.-L., Higashi, R., & Katori, H. (2005) · Nature · doi:10.1038/nature03541 · Cited by 853 · see citing works
The<sup>87</sup>Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129 · see citing works
Flagged first, then by citations
Research works printed but not linked: 18
- [3]3. Bordé, C. J. Base units of the SI, fundamental c onstants and modern quantum physics. Phil. Trans. R. Soc. A 363, 2177-2201 (2005).
- [7]7. Giorgetta, F. R. et al. Optical two-way time and frequency transfer over free space. Nat. Photonics 7, 434438 (2013).
- [9]9. Chou, C. W., Hume, D. B., Koelemeij, J. C. J., Wineland, D. J. & Rosenband, T. Frequency Comparison of Two High-Accuracy Al + Optical Clocks. Phys. Rev. Lett. 104, 070802 (2010).
- [10]10. Huntemann, N. et al. High-Accuracy Optical Clock Based on the Octupole Transition in 171 Yb + . Phys. Rev. Lett. 108, 090801 (2012).
- [11]11. Madej, A. A., Dubé, P., Zhou, Z., Bernard, J. E . & Gertsvolf, M. 88 Sr + 445-THz Single-Ion Reference at the 10 -17 Level via Control and Cancellation of Systematic Uncertainties and Its Measurement against the SI Second. Phys. Rev. Lett. 109, 203002 (2012).
- [12]12. Oskay, W. et al. Single-Atom Optical Clock with High Accuracy. Phys. Rev. Lett. 97, 020801 (2006).
- [16]16. Lemke, N. et al. Spin-1/2 Optical Lattice Clock. Phys. Rev. Lett. 103, 063001 (2009).
- [17]17. Le Targat, R. et al. Experimental realization of an optical second with strontium lattice clocks. Nat. Comm. 4, (2013). doi:10.1038/ncomms3109 · DOI · Paper page
- [21]21. Nicholson, T. L. et al. Comparison of Two Independent Sr Optical Clocks with 1×10 -17 stability at 10 3 s. Phys. Rev. Lett. 109, 230801 (2012).
- [22]22. Hinkley, N. et al. An Atomic Clock with 10 -18 Instability. Science (2013). doi:10.1126/science.1240420 · DOI · Paper page
- [27]27. Lemke, N. D. et al. p-Wave Cold Collisions in an Optical Lattice Clock. Phys. Rev. Lett. 107, 103902 (2011).
- [28]28. Middelmann, T., Falke, S., Lisdat, C. & Sterr, U. High Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock. Phys. Rev. Lett. 109, 263004 (2012).
- [32]32. Yasuda, M. & Katori, H. Lifetime Measurement of the 3 P2 Metastable State of Strontium Atoms. Phys. Rev. Lett. 92, 153004 (2004).
- [33]33. Middelmann, T. et al. Tackling the Blackbody Shift in a Strontium Optical Lattice Clock. IEEE Trans. Instrum. Meas. 60, 2550-2557 (2011).
- [34]34. Boyd, M. et al. 87 Sr Lattice Clock with Inaccuracy below 10 -15 . Phys. Rev. Lett. 98, 083002 (2007).
- [35]35. Westergaard, P. G. et al. Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10 -17 Level. Phys. Rev. Lett. 106, 210801 (2011).
- [36]36. Lodewyck, J., Zawada, M., Lorini, L., Gurov, M. & Lemonde, P. Observation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 59, 411-415 (2012).
- [38]38. Safronova, M. S., Porsev, S. G., Safronova, U. I., Kozlov, M. G. & Clark, C. W. Blackbody-radiation shift in the Sr optical atomic clock. Phys. Rev. A. 87, 012509 (2013).
Cited by
Sorted by citations
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045 · see citing works
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385 · see citing works
Self-citationSystematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · see citing works
Self-citationHuntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677 · see citing works
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · see citing works
Hunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522 · see citing works
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475 · see citing works
Self-citationGodun, R. M., Nisbet-Jones, P. B. R., Jones, J. M., King, S. A., Johnson, L. A. M., Margolis, H. S., Szymaniec, K., Lea, S. N., Bongs, K., & Gill, P. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.210801 · Cited by 468 · see citing works
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · see citing works
Searching for dilaton dark matter with atomic clocks
Arvanitaki, A., Huang, J., & Van Tilburg, K. (2015) · Physical Review D · doi:10.1103/physrevd.91.015015 · Cited by 404 · see citing works
Gravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396 · see citing works
Self-citationA Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384 · see citing works
“For a given lattice laser frequency, we measure the differential ac Stark shift using four interleaved digital servos that lock the clock laser frequency to the atomic resonance for alternating high and low lattice intensities and mF = ±9/2 spin states [23, 121, 56].”
BackgroundMethodInfluentialSelf-citationSpectroscopic observation of SU( <i>N</i> )-symmetric interactions in Sr orbital magnetism
Zhang, X., Bishof, M., Bromley, S. L., Kraus, C. V., Safronova, M. S., Zoller, P., Rey, A. M., & Ye, J. (2014) · Science · doi:10.1126/science.1254978 · Cited by 370 · see citing works
Self-citationBothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324 · see citing works
Self-citationMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263 · see citing works
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253 · see citing works
Geopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245 · see citing works
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238 · see citing works
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221 · see citing works
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211 · see citing works
Self-citationTowards a redefinition of the second based on optical atomic clocks
Riehle, F. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.012 · Cited by 174 · see citing works
High-accuracy coherent optical frequency transfer over a doubled 642-km fiber link
Calonico, D., Bertacco, E. K., Calosso, C. E., Clivati, C., Costanzo, G. A., Frittelli, M., Godone, A., Mura, A., Poli, N., Sutyrin, D. V., et al. (2014) · Applied Physics B · doi:10.1007/s00340-014-5917-8 · Cited by 168 · see citing works
A strontium lattice clock with 3 × 10<sup>−17</sup>inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182 · see citing works
Differential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150 · see citing works
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149 · see citing works
Beloy, K., Hinkley, N., Phillips, N. B., Sherman, J. A., Schioppo, M., Lehman, J., Feldman, A., Hanssen, L. M., Oates, C. W., & Ludlow, A. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.260801 · Cited by 137 · see citing works
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101 · see citing works
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101 · see citing works
Self-citationDenker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91 · see citing works
Comparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85 · see citing works
Strategies for reducing the light shift in atomic clocks
Katori, H., Ovsiannikov, V. D., Marmo, S. I., & Palchikov, V. G. (2015) · Physical Review A · doi:10.1103/physreva.91.052503 · Cited by 74 · see citing works
Intercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64 · see citing works
Frequency and time transfer for metrology and beyond using telecommunication network fibres
Lopez, O., Kéfélian, F., Jiang, H., Haboucha, A., Bercy, A., Stefani, F., Chanteau, B., Kanj, A., Rovera, D., Achkar, J., et al. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.04.005 · Cited by 61 · see citing works
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55 · see citing works
Ground-based optical atomic clocks as a tool to monitor vertical surface motion
Bondarescu, R., Schärer, A., Lundgren, A., Hetényi, G., Houlié, N., Jetzer, P., & Bondarescu, M. (2015) · Geophysical Journal International · doi:10.1093/gji/ggv246 · Cited by 56 · see citing works
Direct comparison of optical lattice clocks with an intercontinental baseline of 9000 km
Hachisu, H., Fujieda, M., Nagano, S., Gotoh, T., Nogami, A., Ido, T., Falke, S., Huntemann, N., Grebing, C., Lipphardt, B., et al. (2014) · Optics Letters · doi:10.1364/ol.39.004072 · Cited by 53 · see citing works
Voigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50 · see citing works
Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link
Hachisu, H., & Ido, T. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.112401 · Cited by 48 · see citing works
Relativistic corrections for time and frequency transfer in optical fibres
Geršl, J., Delva, P., & Wolf, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/552 · Cited by 40 · see citing works
“Atomic clocks have been improving rapidly over the past years and are now reaching stabilities and accuracies of a few parts in 10(18) in fractional frequency [1, 2].”
BackgroundMargolis, H. S., & Gill, P. (2015) · Metrologia · doi:10.1088/0026-1394/52/5/628 · Cited by 40 · see citing works
Shi, C., Robyr, J.-L., Eismann, U., Zawada, M., Lorini, L., Le Targat, R., & Lodewyck, J. (2015) · Physical Review A · doi:10.1103/physreva.92.012516 · Cited by 37 · see citing works
Clock networks for height system unification: a simulation study
Wu, H., Müller, J., & Lämmerzahl, C. (2019) · Geophysical Journal International · doi:10.1093/gji/ggy508 · Cited by 30 · see citing works
Characterization of a 450 km baseline GPS carrier-phase link using an optical fiber link
Droste, S., Grebing, C., Leute, J., Raupach, S. M. F., Matveev, A., Hänsch, T. W., Bauch, A., Holzwarth, R., & Grosche, G. (2015) · New Journal of Physics · doi:10.1088/1367-2630/17/8/083044 · Cited by 29 · see citing works
Shen, Z., Shen, W.-B., & Zhang, S. (2016) · Geophysical Journal International · doi:10.1093/gji/ggw198 · Cited by 29 · see citing works
Shen, Z., Shen, W.-B., & Zhang, S. (2017) · Surveys in Geophysics · doi:10.1007/s10712-017-9414-6 · Cited by 25 · see citing works
Doppler-stabilized fiber link with 6 dB noise improvement below the classical limit
Calosso, C. E., Bertacco, E. K., Calonico, D., Clivati, C., Costanzo, G. A., Frittelli, M., Levi, F., Micalizio, S., Mura, A., & Godone, A. (2015) · Optics Letters · doi:10.1364/ol.40.000131 · Cited by 23 · see citing works
Chronometric measurement of orthometric height differences by means of atomic clocks
Kopeikin, S. M., Kanushin, V. F., Karpik, A. P., Tolstikov, A. S., Gienko, E. G., Goldobin, D. N., Kosarev, N. S., Ganagina, I. G., Mazurova, E. M., Karaush, A. A., et al. (2016) · Gravitation and Cosmology · doi:10.1134/s0202289316030099 · Cited by 21 · see citing works
Faraday-Shielded dc Stark-Shift-Free Optical Lattice Clock
Beloy, K., Zhang, X., McGrew, W. F., Hinkley, N., Yoon, T. H., Nicolodi, D., Fasano, R. J., Schäffer, S. A., Brown, R. C., & Ludlow, A. D. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.183201 · Cited by 20 · see citing works
Self-citationProgress on the optical lattice clock
Ludlow, A. D., & Ye, J. (2015) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2015.03.008 · Cited by 14 · see citing works
Self-citationGué, J., Hees, A., & Wolf, P. (2024) · Physical Review D · doi:10.1103/physrevd.110.035005 · Cited by 10 · see citing works
Bagherbandi, M., Shirazian, M., Amin, H., & Horemuz, M. (2023) · Frontiers in Earth Science · doi:10.3389/feart.2023.1139211 · Cited by 2 · see citing works
“Bloom et al. (2014) demonstrated an atomic clock with a many-atom system that reaches an accuracy of 6×10−18 and could improve the accuracy of optical lattice clocks by a factor of 22.”
Background
- Authors
- Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- California Institute of Technology (US)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature
- Published
- 2014-01-22
- Volume
- 506
- Issue
- 7486
- Pages
- 71-75
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2036614989
- Cited by
- 1,073
- References
- 3
- Citations by year
- 2026: 38 · 2025: 61 · 2024: 61 · 2023: 63 · 2022: 49 · 2021: 72 · 2020: 65 · 2019: 81 · 2018: 97 · 2017: 90 · 2016: 130 · 2015: 158 · 2014: 104 · 2013: 4
- FWCI
- 79.95
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Durham Research Online (Durham University) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- optical lattice clock, strontium atoms, clock accuracy, clock stability, systematic uncertainties, blackbody radiation, primary frequency standard, measurement time reduction, variation of fundamental constants, quantum sensors, many-body systems, precision measurement, trapped ions, quantum information
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review