Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record.

Charge Inversion and Flow Reversal in a Nanochannel Electro-osmotic Flow

Qiao, R., Aluru, N. R.·2004·Physical Review Letters

Abstract

Ion distribution and velocity profiles for electro-osmotic flow in a 3.49 nm wide slit channel with a surface charge density of -0.285 C/m(2) are studied using molecular dynamics simulations. Simulation results indicate that the concentration of the co-ion exceeds that of the counterion in the region 0.53 nm away from the channel wall, and the electro-osmotic flow is in the opposite direction to that predicted by the classical continuum theory. The charge inversion is mainly caused by the molecular nature of water and ions. The flow reversal is caused by the immobilization of counterions adsorbed on the channel wall and due to the charge inversion phenomena.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.92.198301

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Qiao, R., & Aluru, N. R.
Venue
Physical Review Letters
Published
2004-05-10
Volume
92
Issue
19
Pages
198301-198301
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W1963726488
Cited by
236
References
0
FWCI
6.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Charge Inversion and Flow Reversal in a Nanochannel Electro-osmotic Flow. https://app.cochat.ai/papers/10.1103/physrevlett.92.198301
The paper
Qiao, R., & Aluru, N. R. (2004). Charge Inversion and Flow Reversal in a Nanochannel Electro-osmotic Flow. Physical Review Letters. https://doi.org/10.1103/physrevlett.92.198301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.