Measurement of theHg+1995d96s2 D5/22Electric Quadrupole Moment and a Constraint on the Quadrupole Shift
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The electric-quadrupole moment of the (199)Hg+ 5d9 6s2 (2)D(5/2) state is measured to be theta(D,5/2) = -2.29(8) x 10(-40) C m2. This value was determined by measuring the frequency of the (199)Hg+ 5d10 6s (2)S(1/2) --> 5d9 6s2 (2)D(5/2) optical clock transition for different applied electric-field gradients. An isolated, mechanically stable optical cavity provides a frequency reference for the measurement. We compare the results with theoretical calculations and discuss the implications for the accuracy of an atomic clock based upon this transition. We now expect that the frequency shift caused by the interaction of the quadrupole moment with stray electric-field gradients will not limit the accuracy of the Hg+ optical clock at the 10(-18) level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationSearch for Variations of Fundamental Constants using Atomic Fountain Clocks
Marion, H., Pereira Dos Santos, F., Abgrall, M., Zhang, S., Sortais, Y., Bize, S., Maksimovic, I., Calonico, D., Grünert, J., Mandache, C., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150801 · Cited by 298
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citation‘Designer atoms’ for quantum metrology
Roos, C. F., Chwalla, M., Kim, K., Riebe, M., & Blatt, R. (2006) · Nature · doi:10.1038/nature05101 · Cited by 343
Single-Atom Optical Clock with High Accuracy
Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.020801 · Cited by 297
Self-citationFortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citation
Metadata
- Authors
- Oskay, W., Itano, W., & Bergquist, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-04-26
- Volume
- 94
- Issue
- 16
- Pages
- 163001-163001
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1543484312
- Cited by
- 73
- References
- 2
- FWCI
- 7.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.