The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band
Open accessAbstract
We propose and demonstrate a coherent control scheme for stable phase locking of squeezed vacuum fields. We focus on sideband fields at frequencies from 10 Hz to 10 kHz, which is a frequency regime of particular interest in gravitational-wave detection and for which conventional control schemes have failed so far. A vacuum field with broadband squeezing covering this entire band was produced using optical parametric oscillation and characterized with balanced homodyne detection. The system was stably controlled over long periods utilizing two coherent but frequency shifted control fields. In order to demonstrate the performance of our setup the squeezed field was used for a nonclassical sensitivity improvement of a Michelson interferometer at audio frequencies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Cited by
Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light
Aasi, J., Abadie, J., Abbott, B. P., Abbott, R., Abbott, T. D., Abernathy, M. R., Adams, C., Adams, T., Addesso, P., Adhikari, R. X., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.177 · Cited by 1,204
Self-citationA gravitational wave observatory operating beyond the quantum shot-noise limit
The LIGO Scientific Collaboration, Abadie, J., Abbott, B. P., Abbott, R., Abbott, T. D., Abernathy, M., Adams, C., Adhikari, R., Affeldt, C., Allen, B., et al. (2011) · Nature Physics · doi:10.1038/nphys2083 · Cited by 921
Self-citationObservation of Squeezed Light with 10-dB Quantum-Noise Reduction
Vahlbruch, H., Mehmet, M., Chelkowski, S., Hage, B., Franzen, A., Lastzka, N., Goßler, S., Danzmann, K., & Schnabel, R. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.033602 · Cited by 473
Self-citationThe third generation of gravitational wave observatories and their science reach
Punturo, M., Abernathy, M., Acernese, F., Allen, B., Andersson, N., Arun, K., Barone, F., Barr, B., Barsuglia, M., Beker, M., et al. (2010) · Classical and Quantum Gravity · doi:10.1088/0264-9381/27/8/084007 · Cited by 431
Self-citationFirst Long-Term Application of Squeezed States of Light in a Gravitational-Wave Observatory
Grote, H., Danzmann, K., Dooley, K. L., Schnabel, R., Slutsky, J., & Vahlbruch, H. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.181101 · Cited by 379
Self-citation
Metadata
- Authors
- Vahlbruch, H., Chelkowski, S., Hage, B., Franzen, A., Danzmann, K., & Schnabel, R.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-07-06
- Volume
- 97
- Issue
- 1
- Pages
- 011101-011101
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2137698445
- Cited by
- 225
- References
- 1
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band. https://app.cochat.ai/papers/10.1103/physrevlett.97.011101
- The paper
- Vahlbruch, H., Chelkowski, S., Hage, B., Franzen, A., Danzmann, K., & Schnabel, R. (2006). Coherent Control of Vacuum Squeezing in the Gravitational-Wave Detection Band. Physical Review Letters. https://doi.org/10.1103/physrevlett.97.011101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.