Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record.

High-Resolution Confocal Microscopy by Saturated Excitation of Fluorescence

Fujita, Katsumasa, Kobayashi, Minoru, Kawano, Shogo, Yamanaka, Masahito, Kawata, Satoshi·2007·Physical Review Letters

Abstract

We demonstrate the use of saturated excitation in confocal fluorescence microscopy to improve the spatial resolution. In the proposed technique, we modulate the excitation intensity temporally and detect the harmonic modulation of the fluorescence signal which is caused by the saturated excitation in the center of the laser focus. Theoretical and experimental investigations show that the demodulated fluorescence signal is nonlinearly proportional to the excitation intensity and contributes to improve the spatial resolution in three dimensions beyond the diffraction limit of light.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.99.228105

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Fujita, K., Kobayashi, M., Kawano, S., Yamanaka, M., & Kawata, S.
Venue
Physical Review Letters
Published
2007-11-30
Volume
99
Issue
22
Pages
228105-228105
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2041080207
Cited by
219
References
0
FWCI
4.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Resolution Confocal Microscopy by Saturated Excitation of Fluorescence. https://app.cochat.ai/papers/10.1103/physrevlett.99.228105
The paper
Fujita, K., Kobayashi, M., Kawano, S., Yamanaka, M., & Kawata, S. (2007). High-Resolution Confocal Microscopy by Saturated Excitation of Fluorescence. Physical Review Letters. https://doi.org/10.1103/physrevlett.99.228105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.