The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Multivariate optimization of a high brightness dc gun photoinjector
Open accessAbstract
We have conducted a multiobjective computational optimization of a high brightness, high average current photoinjector under development at Cornell University. This injector employs a dc photoemission electron gun. Using evolutionary algorithms combined with parallel computing resources, the multivariate parameter space of the photoinjector was explored for optimal values. This powerful computational tool allows an extensive study of complex and nonlinear systems such as the space-charge dominated regions of an accelerator, and has broad areas of potential application to accelerator physics and engineering problems. In the present case, the optimized injector is simulated to deliver beam of very high quality (e.g., a rms normalized emittance of 0.1 mm mrad for 0.1 nC, and 0.7 mm mrad for 1 nC bunches). The field strengths of the active elements of the injector are moderate and technically practical. The relevance of these results to various novel linac-based accelerator proposals is pointed out.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and elitist multiobjective genetic algorithm: NSGA-II
Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T. (2002) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.996017 · Cited by 50,053
Superconducting TESLA cavities
Aune, B., Bandelmann, R., Bloess, D., Bonin, B., Bosotti, A., Champion, M., Crawford, C., Deppe, G., Dwersteg, B., Edwards, D. A., et al. (2000) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.3.092001 · Cited by 444
Cited by
Cathode R&D for future light sources
Dowell, D. H., Bazarov, I., Dunham, B., Harkay, K., Hernandez-Garcia, C., Legg, R., Padmore, H., Rao, T., Smedley, J., & Wan, W. (2010) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2010.03.104 · Cited by 286
Self-citationA Proposal for an X-Ray Free-Electron Laser Oscillator with an Energy-Recovery Linac
Kim, K.-J., Shvyd’ko, Y., & Reiche, S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.244802 · Cited by 282
Robust simplex algorithm for online optimization
Huang, X. (2018) · Physical Review Accelerators and Beams · doi:10.1103/physrevaccelbeams.21.104601 · Cited by 30
Metadata
- Authors
- Bazarov, I. V., & Sinclair, C. K.
- Venue
- Physical Review Special Topics - Accelerators and Beams
- Publisher
- American Physical Society (APS)
- Published
- 2005-03-24
- Volume
- 8
- Issue
- 3
- ISSN
- 1098-4402 (ISSN-L)
- OpenAlex
- W2095602000
- Cited by
- 183
- References
- 2
- FWCI
- 26.14
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multivariate optimization of a high brightness dc gun photoinjector. https://app.cochat.ai/papers/10.1103/physrevstab.8.034202
- The paper
- Bazarov, I. V., & Sinclair, C. K. (2005). Multivariate optimization of a high brightness dc gun photoinjector. Physical Review Special Topics - Accelerators and Beams. https://doi.org/10.1103/physrevstab.8.034202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.