Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 232

The DOI matches its Crossref record.

Analysis of Variance of the 1952 Data on the Atomic Constants and a New Adjustment, 1955

Cohen, E. Richard, DuMond, Jesse W., Layton, Thomas W., Rollett, John S.·1955·Reviews of Modern Physics

Abstract

The 1952 data used by DuMond and Cohen in an evaluation of the atomic constants are analyzed for the presence of systematic errors by a variance analysis performed by an electronic digital computer. For simplicity the velocity of light is treated as a fixed constant of known value and there remain then eleven linear equations in four unknowns subject to least-squares adjustment. Least-squares adjustments of 219 over-determined subsets of these equations have been made and ${\ensuremath{\chi}}^{2}$ has been evaluated for each such subset. An analysis of these data indicates that small systematic errors are most likely to exist in the following input data: (1) The determination of the Faraday by the silver voltameter. (2) The determination of the cyclotron resonance frequency of the proton by the inverse cyclotron method of Bloch and Jeffreys. (3) Certain of the higher voltage determinations of $\frac{h}{e}$ by the continuous x-ray quantum limit. In descending order of magnitude of discrepancy from the remaining data on the constants are the determinations of (a) Felt, Harris, and DuMond made at 24 500 volts, (b) Bearden and Schwarz at 19 600 volts, (c) Bearden and Schwarz and also Bearden, Johnson, and Watts in the region between about 10 kv and about 6 kv. An analysis of the various observations taken by these observers at different voltages reveals a possible systematic trend when discrepancy is plotted against either voltage or window width in volts. Conjectures to account for the effect are discussed.The modifications called for by this analysis yield a new 1955 adjustment in which ${\ensuremath{\chi}}^{2}$ is smaller than it was for the November, 1952 adjustment. The new ${\ensuremath{\chi}}^{2}=3.25$ is satisfactorily close to its expected value, 3. Thanks to the fact that the error measures adopted in the November, 1952 adjustment for the output values were conservatively based on the criterion of external consistency, the changes in the values occasioned as a result of the present analysis are all well within those estimated limits. A welcome effect of this new adjustment is that the adjusted output value of $\frac{{\ensuremath{\lambda}}_{g}}{{\ensuremath{\lambda}}_{s}}$, the conversion factor from Siegbahn's $x$-units to milliangstroms, now lies much closer to the input value. A new table of constants and conversion factors is presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/revmodphys.27.363

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 232

Metadata

Authors
Cohen, E. R., DuMond, J. W., Layton, T. W., & Rollett, J. S.
Venue
Reviews of Modern Physics
Published
1955-10-01
Volume
27
Issue
4
Pages
363-380
ISSN
0034-6861 (ISSN-L)
OpenAlex
W2009033448
Cited by
232
References
0
FWCI
61.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of Variance of the 1952 Data on the Atomic Constants and a New Adjustment, 1955. https://app.cochat.ai/papers/10.1103/revmodphys.27.363
The paper
Cohen, E. R., DuMond, J. W., Layton, T. W., & Rollett, J. S. (1955). Analysis of Variance of the 1952 Data on the Atomic Constants and a New Adjustment, 1955. Reviews of Modern Physics. https://doi.org/10.1103/revmodphys.27.363

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.