Fundamental Understanding of Piezoelectric Strain Sensors
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
This paper investigates the behavior of piezoelectric elements as strain sensors. Strain is measured in terms of the charge generated by the element as a result of the direct piezoelectric effect. Strain measurements from piezoceramic (PZT) and piezofilm (PVDF) sensors are compared with strains from a conventional foil strain gage and the advantages of each type of sensor are discussed, along with their limitations. The sensors are surface bonded to a beam and are calibrated over a frequency range of 5-500 Hz. Correction factors to account for transverse strain and shear lag effects due to the bond layer are analytically derived and experimentally validated. The effect of temperature on the output of PZT strain sensors is investigated. Additionally, design of signal conditioning electronics to collect the signals from the piezoelectric sensors is addressed. The superior performance of piezoelectric sensors compared to conventional strain gages in terms of sensitivity and signal to noise ratio is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Use of piezoelectric actuators as elements of intelligent structures
Crawley, E. F., & de Luis, J. (1987) · AIAA Journal · doi:10.2514/3.9792 · Cited by 2,602
IEEE Standard on Piezoelectricity
(2008) · doi:10.1109/ieeestd.1988.79638 · Cited by 951
A Self-Sensing Piezoelectric Actuator for Collocated Control
Dosch, J. J., Inman, D. J., & Garcia, E. (1992) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9200300109 · Cited by 767
Instrumentation for engineering measurements
(1993) · Measurement · doi:10.1016/0263-2241(93)90027-f · Cited by 181
Instrumentation for Engineering Measurements
Daly, J., Riley, W. F., McConnell, K. G., & Saunders, H. (1986) · Journal of vibration and acoustics · doi:10.1115/1.3269378 · Cited by 146
Vibration Control of a Cylindrical Shell Using Distributed Piezoelectric Sensors and Actuators
Qiu, J., & Tani, J. (1995) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9500600404 · Cited by 71
Samuel, P. D., & Pines, D. J. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.275681 · Cited by 18
Cited by
Direct-Write Piezoelectric Polymeric Nanogenerator with High Energy Conversion Efficiency
Chang, C., Tran, V. H., Wang, J., Fuh, Y.-K., & Lin, L. (2010) · Nano Letters · doi:10.1021/nl9040719 · Cited by 1,379
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Park, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 939
Review of experimental techniques for high rate deformation and shock studies
Field, J. E., Walley, S. M., Proud, W. G., Goldrein, H. T., & Siviour, C. R. (2004) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2004.03.005 · Cited by 806
Wang, X.-X., Yu, G.-F., Zhang, J., Yu, M., Ramakrishna, S., & Long, Y.-Z. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100704 · Cited by 447
Metadata
- Authors
- Sirohi, J., & Chopra, I.
- Venue
- Journal of Intelligent Material Systems and Structures
- Publisher
- SAGE Publications
- Published
- 2000-04
- Volume
- 11
- Issue
- 4
- Pages
- 246-257
- ISSN
- 1045-389X (ISSN-L)
- 1530-8138
- OpenAlex
- W2107890555
- Cited by
- 777
- References
- 7
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.