The DOI matches its Crossref record.
Small-angle X-ray scattering station at the SPring-8 RIKEN beamline
Abstract
RIKEN beamline I (BL45XU) is an undulator beamline with two branches. One is for protein crystallography (PX) and the other is for small-angle x-ray scattering (SAXS). The beam is split into the two branches by a diamond monochromator so that two experiments can be done simultaneously [Yamamoto et al. (1995) Rev. Sci. Instrum. 66, 1833-1835]. The SAXS branch was designed for studying the weak interaction of proteins or subunits of fibrous or protein solutions especially using hydrostatic pressure. The optics makes use of the good parallelism of the undulator beam in order to reduce parasitic scattering. The beamline consists of a double crystal monochromator and a K-B type focusing mirror system. In order to cope with the high flux of the beam, an x-ray image intensifier (Hamamatsu Photonics, V5445P) with a cooled CCD camera (C4880-82) was used. As a result, decreases in both collection time and sample amount were realized in standard static experiments. These improvements will greatly facilitate SAXS experiments under high pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kim, Y. S., Liu, M., Ishida, Y., Ebina, Y., Osada, M., Sasaki, T., Hikima, T., Takata, M., & Aida, T. (2015) · Nature Materials · doi:10.1038/nmat4363 · Cited by 655
Layered nanocomposites by shear-flow-induced alignment of nanosheets
Zhao, C., Zhang, P., Zhou, J., Qi, S., Yamauchi, Y., Shi, R., Fang, R., Ishida, Y., Wang, S., Tomsia, A. P., et al. (2020) · Nature · doi:10.1038/s41586-020-2161-8 · Cited by 548
A low-background-intensity focusing small-angle X-ray scattering undulator beamline
Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013) · Journal of Applied Crystallography · doi:10.1107/s002188981302774x · Cited by 530
Crystal structure of the human centromeric nucleosome containing CENP-A
Tachiwana, H., Kagawa, W., Shiga, T., Osakabe, A., Miya, Y., Saito, K., Hayashi-Takanaka, Y., Oda, T., Sato, M., Park, S.-Y., et al. (2011) · Nature · doi:10.1038/nature10258 · Cited by 395
Nishino, Y., Eltsov, M., Joti, Y., Ito, K., Takata, H., Takahashi, Y., Hihara, S., Frangakis, A. S., Imamoto, N., Ishikawa, T., et al. (2012) · The EMBO Journal · doi:10.1038/emboj.2012.35 · Cited by 338
Metadata
- Authors
- Fujisawa, T., Inoue, K., Oka, T., Iwamoto, H., Uruga, T., Kumasaka, T., Inoko, Y., Yagi, N., Yamamoto, M., & Ueki, T.
- Venue
- Journal of Applied Crystallography
- Published
- 2000-06-01
- Volume
- 33
- Issue
- 3
- Pages
- 797-800
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1969947371
- Cited by
- 179
- References
- 0
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small-angle X-ray scattering station at the SPring-8 RIKEN beamline. https://app.cochat.ai/papers/10.1107/s002188980000131x
- The paper
- Fujisawa, T., Inoue, K., Oka, T., Iwamoto, H., Uruga, T., Kumasaka, T., Inoko, Y., Yagi, N., Yamamoto, M., & Ueki, T. (2000). Small-angle X-ray scattering station at the SPring-8 RIKEN beamline. Journal of Applied Crystallography. https://doi.org/10.1107/s002188980000131x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.