The DOI matches its Crossref record.
A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering
Abstract
A commercially available small-angle X-ray scattering camera, NanoSTAR from Bruker AXS, has been modified to optimize its use for weakly scattering solution samples. The original NanoSTAR is a pinhole camera with two Göbel mirrors for monochromating and making the beam parallel, and with a two-dimensional position-sensitive gas detector (HiSTAR) for data collection. The instrument has one integrated vacuum. It was constructed for position-resolved studies and thus has a small beam size at the sample position. In the present work, the instrumental configuration has been optimized by numerical calculations based on phase-space analysis and Monte Carlo simulations in order to obtain a higher flux. This has led to a setup in which the beam at the sample is larger and the collimation part of the instrument is longer, so that divergence of the beam is similar to that of the original camera. An extra pinhole is included after the Göbel mirrors to make the beam size well defined after the mirrors. The camera thus has genuine three-pinhole collimation. The use of electron-microscope pinholes minimizes parasitic scattering. At the University of Aarhus, the modified camera is installed on a powerful rotating-anode X-ray source (MacScience 6 kW Cu with a 0.3 × 0.3 mm effective source size). Measurements have been performed on a wide variety of weakly scattering samples, such as surfactant micelles, homopolymer solutions, block copolymer micelles, proteins etc. The data are routinely converted to absolute scale using the scattering from water as a primary standard. The standard configuration covers the range of scattering vectors from 0.01 to 0.35 Å−1 with a flux of 1.7 × 10 7 photons s−1 for Cu K α radiation at a generator power of 4.05 kW. The camera is easily converted to a high-resolution version covering 0.0037 to 0.22 Å−1 with a loss of flux of about a factor of 10, as well as to a position-resolved version.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Self-assembly of a nanoscale DNA box with a controllable lid
Andersen, E. S., Dong, M., Nielsen, M. M., Jahn, K., Subramani, R., Mamdouh, W., Golas, M. M., Sander, B., Stark, H., Oliveira, C. L. P., et al. (2009) · Nature · doi:10.1038/nature07971 · Cited by 1,627
Self-citationA low-background-intensity focusing small-angle X-ray scattering undulator beamline
Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013) · Journal of Applied Crystallography · doi:10.1107/s002188981302774x · Cited by 530
Fehér, B., Zhu, K., Nyström, B., Varga, I., & Pedersen, J. S. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b01896 · Cited by 35
Self-citation
Metadata
- Authors
- Pedersen, J. S.
- Venue
- Journal of Applied Crystallography
- Published
- 2004-05-11
- Volume
- 37
- Issue
- 3
- Pages
- 369-380
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2088480703
- Cited by
- 231
- References
- 0
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering. https://app.cochat.ai/papers/10.1107/s0021889804004170
- The paper
- Pedersen, J. S. (2004). A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889804004170
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.