Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 231

The DOI matches its Crossref record.

A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering

Pedersen, Jan Skov·2004·Journal of Applied Crystallography

Abstract

A commercially available small-angle X-ray scattering camera, NanoSTAR from Bruker AXS, has been modified to optimize its use for weakly scattering solution samples. The original NanoSTAR is a pinhole camera with two Göbel mirrors for monochromating and making the beam parallel, and with a two-dimensional position-sensitive gas detector (HiSTAR) for data collection. The instrument has one integrated vacuum. It was constructed for position-resolved studies and thus has a small beam size at the sample position. In the present work, the instrumental configuration has been optimized by numerical calculations based on phase-space analysis and Monte Carlo simulations in order to obtain a higher flux. This has led to a setup in which the beam at the sample is larger and the collimation part of the instrument is longer, so that divergence of the beam is similar to that of the original camera. An extra pinhole is included after the Göbel mirrors to make the beam size well defined after the mirrors. The camera thus has genuine three-pinhole collimation. The use of electron-microscope pinholes minimizes parasitic scattering. At the University of Aarhus, the modified camera is installed on a powerful rotating-anode X-ray source (MacScience 6 kW Cu with a 0.3 × 0.3 mm effective source size). Measurements have been performed on a wide variety of weakly scattering samples, such as surfactant micelles, homopolymer solutions, block copolymer micelles, proteins etc. The data are routinely converted to absolute scale using the scattering from water as a primary standard. The standard configuration covers the range of scattering vectors from 0.01 to 0.35 Å−1 with a flux of 1.7 × 10 7 photons s−1 for Cu K α radiation at a generator power of 4.05 kW. The camera is easily converted to a high-resolution version covering 0.0037 to 0.22 Å−1 with a loss of flux of about a factor of 10, as well as to a position-resolved version.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0021889804004170

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
Pedersen, J. S.
Venue
Journal of Applied Crystallography
Published
2004-05-11
Volume
37
Issue
3
Pages
369-380
ISSN
0021-8898 (ISSN-L)
OpenAlex
W2088480703
Cited by
231
References
0
FWCI
6.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering. https://app.cochat.ai/papers/10.1107/s0021889804004170
The paper
Pedersen, J. S. (2004). A flux- and background-optimized version of the NanoSTAR small-angle X-ray scattering camera for solution scattering. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889804004170

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.