The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Size–strain line-broadening analysis of the ceria round-robin sample
Open accessAbstract
The results of both a line-broadening study on a ceria sample and a size–strain round robin on diffraction line-broadening methods, which was sponsored by the Commission on Powder Diffraction of the International Union of Crystallography, are presented. The sample was prepared by heating hydrated ceria at 923 K for 45 h. Another ceria sample was prepared to correct for the effects of instrumental broadening by annealing commercially obtained ceria at 1573 K for 3 h and slowly cooling it in the furnace. The diffraction measurements were carried out with two laboratory and two synchrotron X-ray sources, two constant-wavelength neutron and a time-of-flight (TOF) neutron source. Diffraction measurements were analyzed by three methods: the model assuming a lognormal size distribution of spherical crystallites, Warren–Averbach analysis and Rietveld refinement. The last two methods detected a relatively small strain in the sample, as opposed to the first method. Assuming a strain-free sample, the results from all three methods agree well. The average real crystallite size, on the assumption of a spherical crystallite shape, is 191 (5) Å. The scatter of results given by different instruments is relatively small, although significantly larger than the estimated standard uncertainties. The Rietveld refinement results for this ceria sample indicate that the diffraction peaks can be successfully approximated with a pseudo-Voigt function. In a common approximation used in Rietveld refinement programs, this implies that the size-broadened profile cannot be approximated by a Lorentzian but by a full Voigt or pseudo-Voigt function. In the second part of this paper, the results of the round robin on the size–strain line-broadening analysis methods are presented, which was conducted through the participation of 18 groups from 12 countries. Participants have reported results obtained by analyzing data that were collected on the two ceria samples at seven instruments. The analysis of results received in terms of coherently diffracting, both volume-weighted and area-weighted apparent domain size are reported. Although there is a reasonable agreement, the reported results on the volume-weighted domain size show significantly higher scatter than those on the area-weighted domain size. This is most likely due to a significant number of results reporting a high value of strain. Most of those results were obtained by Rietveld refinement in which the Gaussian size parameter was not refined, thus erroneously assigning size-related broadening to other effects. A comparison of results with the average of the three-way comparative analysis from the first part shows a good agreement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warren, Β. E. (1968) · Cited by 5,832
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
Rietveld refinement of Debye–Scherrer synchrotron X-ray data from Al2O3
Thompson, P., Cox, D. E., & Hastings, J. B. (1987) · Journal of Applied Crystallography · doi:10.1107/s0021889887087090 · Cited by 2,820
Young, R. A. (1993) · Crystal Research and Technology · Cited by 2,581
KAJI, K. (1975) · Sen'i Gakkaishi · doi:10.2115/fiber.31.7_p204 · Cited by 2,462
A fundamental parameters approach to X-ray line-profile fitting
Cheary, R. W., & Coelho, A. (1992) · Journal of Applied Crystallography · doi:10.1107/s0021889891010804 · Cited by 1,660
A correction for powder diffraction peak asymmetry due to axial divergence
Finger, L. W., Cox, D. E., & Jephcoat, A. P. (1994) · Journal of Applied Crystallography · doi:10.1107/s0021889894004218 · Cited by 1,242
Ungár, T., Gubicza, J., Ribárik, G., & Borbély, A. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889801003715 · Cited by 789
A rapid method for analysing the breadths of diffraction and spectral lines using the Voigt function
Langford, J. I. (1978) · Journal of Applied Crystallography · doi:10.1107/s0021889878012601 · Cited by 625
Self-citationX-Ray and Neutron Diffraction in Nonideal Crystals
Krivoglaz, M. A. (1996) · Springer eBooks · doi:10.1007/978-3-642-74291-0 · Cited by 602
Cited by
Precise calculation of crystallite size of nanomaterials: A review
Hassanzadeh-Tabrizi, S. A. (2023) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2023.171914 · Cited by 649
Uvarov, V., & Popov, I. (2013) · Materials Characterization · doi:10.1016/j.matchar.2013.09.002 · Cited by 537
Size-Dependent Extinction Coefficients of PbS Quantum Dots
Cademartiri, L., Montanari, E., Calestani, G., Migliori, A., Guagliardi, A., & Ozin, G. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063166u · Cited by 454
Uvarov, V., & Popov, I. (2007) · Materials Characterization · doi:10.1016/j.matchar.2006.09.002 · Cited by 443
Hou, Y., Li, X., Zhao, Q., Quan, X., & Chen, G. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200902390 · Cited by 335
Metadata
- Authors
- Balzar, D., Audebrand, N., Daymond, M. R., Fitch, A., Hewat, A., Langford, J. I., Le Bail, A., Louër, D., Masson, O., McCowan, C. N., Popa, N. C., Stephens, P. W., & Toby, B. H.
- Venue
- Journal of Applied Crystallography
- Published
- 2004-11-11
- Volume
- 37
- Issue
- 6
- Pages
- 911-924
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2106729829
- Cited by
- 537
- References
- 17
- FWCI
- 8.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size–strain line-broadening analysis of the ceria round-robin sample. https://app.cochat.ai/papers/10.1107/s0021889804022551
- The paper
- Balzar, D., Audebrand, N., Daymond, M. R., Fitch, A., Hewat, A., Langford, J. I., Le Bail, A., Louër, D., Masson, O., McCowan, C. N., Popa, N. C., Stephens, P. W., & Toby, B. H. (2004). Size–strain line-broadening analysis of the ceria round-robin sample. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889804022551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.