Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record.

Upgrade of the small-angle X-ray scattering beamline X33 at the European Molecular Biology Laboratory, Hamburg

Open access
Roessle, Manfred W., Klaering, Robbert, Ristau, Uwe, Robrahn, Bernd, Jahn, Doris, Gehrmann, Thomas, Konarev, Petr, Round, Adam, Fiedler, Stefan, Hermes, Christoph, Svergun, Dmitri·2007·Journal of Applied Crystallography

Abstract

The small-angle X-ray scattering beamline X33 of the European Molecular Biology Laboratory (EMBL) at the DORIS III storage ring [Deutsches Elektronen Synchrotron (DESY) Hamburg] was used for more than two decades to study the structure of non-crystalline biological systems. During recent years the beamline's scope has changed and is now predominantly used to analyze solutions of biological macromolecules. Owing to renewed interest in solution scattering studies from the biological community, the workload on the beamline has steadily increased. A major upgrade of X33 was performed to improve the beamline stability and data quality, to shorten the measurement time and to ensure user-friendly operation. The upgrade involved all major components of the beamline, including the optical system (monochromator, mirror, slits, beam monitors), electronics, control and acquisition software, X-ray detector system and the sample environment. The upgrade improved the brilliance by a factor of about three and the measuring time was reduced by a factor of seven. The knowledge and experience gained during the implementation of the upgrades to X33, may aid the design process for the BioSAXS beamline to be constructed for the PETRA-3 facility at DESY.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0021889806055506

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 235

Metadata

Authors
Roessle, M. W., Klaering, R., Ristau, U., Robrahn, B., Jahn, D., Gehrmann, T., Konarev, P., Round, A., Fiedler, S., Hermes, C., & Svergun, D.
Venue
Journal of Applied Crystallography
Published
2007-01-26
Volume
40
Issue
s1
Pages
s190-s194
ISSN
0021-8898 (ISSN-L)
OpenAlex
W2096032513
Cited by
235
References
0
FWCI
18.47
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Upgrade of the small-angle X-ray scattering beamline X33 at the European Molecular Biology Laboratory, Hamburg. https://app.cochat.ai/papers/10.1107/s0021889806055506
The paper
Roessle, M. W., Klaering, R., Ristau, U., Robrahn, B., Jahn, D., Gehrmann, T., Konarev, P., Round, A., Fiedler, S., Hermes, C., & Svergun, D. (2007). Upgrade of the small-angle X-ray scattering beamline X33 at the European Molecular Biology Laboratory, Hamburg. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889806055506

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.