The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY)
Open accessAbstract
A high-brilliance synchrotron P12 beamline of the EMBL located at the PETRA III storage ring (DESY, Hamburg) is dedicated to biological small-angle X-ray scattering (SAXS) and has been designed and optimized for scattering experiments on macromolecular solutions. Scatterless slits reduce the parasitic scattering, a custom-designed miniature active beamstop ensures accurate data normalization and the photon-counting PILATUS 2M detector enables the background-free detection of weak scattering signals. The high flux and small beam size allow for rapid experiments with exposure time down to 30–50 ms covering the resolution range from about 300 to 0.5 nm. P12 possesses a versatile and flexible sample environment system that caters for the diverse experimental needs required to study macromolecular solutions. These include an in-vacuum capillary mode for standard batch sample analyses with robotic sample delivery and for continuous-flow in-line sample purification and characterization, as well as an in-air capillary time-resolved stopped-flow setup. A novel microfluidic centrifugal mixing device (SAXS disc) is developed for a high-throughput screening mode using sub-microlitre sample volumes. Automation is a key feature of P12; it is controlled by a beamline meta server, which coordinates and schedules experiments from either standard or nonstandard operational setups. The integrated SASFLOW pipeline automatically checks for consistency, and processes and analyses the data, providing near real-time assessments of overall parameters and the generation of low-resolution models within minutes of data collection. These advances, combined with a remote access option, allow for rapid high-throughput analysis, as well as time-resolved and screening experiments for novice and expert biological SAXS users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
(2016) · Encyclopedia of Nanotechnology · doi:10.1007/978-94-017-9780-1_101037 · Cited by 3,780
Svergun, D., Barberato, C., & Koch, M. H. J. (1995) · Journal of Applied Crystallography · doi:10.1107/s0021889895007047 · Cited by 3,434
Self-citationSvergun, D. I. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77443-6 · Cited by 2,221
Self-citationDAMMIF , a program for rapid ab-initio shape determination in small-angle scattering
Franke, D., & Svergun, D. I. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809000338 · Cited by 2,021
Self-citationHow fast-folding proteins fold
Lindorff-Larsen, K., Piana, S., Dror, R. O., & Shaw, D. E. (2011) · Science · doi:10.1126/science.1208351 · Cited by 1,980
Uniqueness of ab initio shape determination in small-angle scattering
Volkov, V. V., & Svergun, D. I. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889803000268 · Cited by 1,932
Self-citationAutomated matching of high- and low-resolution structural models
Kozin, M. B., & Svergun, D. I. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889800014126 · Cited by 1,302
Self-citationA low-background-intensity focusing small-angle X-ray scattering undulator beamline
Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013) · Journal of Applied Crystallography · doi:10.1107/s002188981302774x · Cited by 530
Small-Angle X-ray Scattering of Polymers
Chu, B., & Hsiao, B. S. (2001) · Chemical Reviews · doi:10.1021/cr9900376 · Cited by 455
Cited by
Franke, D., Petoukhov, M. V., Konarev, P. V., Panjkovich, A., Tuukkanen, A., Mertens, H. D. T., Kikhney, A. G., Hajizadeh, N. R., Franklin, J. M., Jeffries, C. M., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717007786 · Cited by 1,329
Self-citationATSAS 3.0: expanded functionality and new tools for small-angle scattering data analysis
Manalastas-Cantos, K., Konarev, P. V., Hajizadeh, N. R., Kikhney, A. G., Petoukhov, M. V., Molodenskiy, D. S., Panjkovich, A., Mertens, H. D. T., Gruzinov, A., Borges, C., et al. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576720013412 · Cited by 964
Self-citationHopkins, J. B., Gillilan, R. E., & Skou, S. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717011438 · Cited by 646
Trewhella, J., Duff, A. P., Durand, D., Gabel, F., Guss, J. M., Hendrickson, W. A., Hura, G. L., Jacques, D. A., Kirby, N. M., Kwan, A. H., et al. (2017) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798317011597 · Cited by 285
Self-citationSmall-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Self-citation
Metadata
- Authors
- Blanchet, C. E., Spilotros, A., Schwemmer, F., Graewert, M. A., Kikhney, A., Jeffries, C. M., Franke, D., Mark, D., Zengerle, R., Cipriani, F., Fiedler, S., Roessle, M., & Svergun, D. I.
- Venue
- Journal of Applied Crystallography
- Published
- 2015-03-12
- Volume
- 48
- Issue
- 2
- Pages
- 431-443
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W2150576297
- Cited by
- 589
- References
- 41
- FWCI
- 18.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY). https://app.cochat.ai/papers/10.1107/s160057671500254x
- The paper
- Blanchet, C. E., Spilotros, A., Schwemmer, F., Graewert, M. A., Kikhney, A., Jeffries, C. M., Franke, D., Mark, D., Zengerle, R., Cipriani, F., Fiedler, S., Roessle, M., & Svergun, D. I. (2015). Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY). Journal of Applied Crystallography. https://doi.org/10.1107/s160057671500254x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.