The DOI matches its Crossref record.
Accuracy of molecular mass determination of proteins in solution by small-angle X-ray scattering
Open accessAbstract
One of the most important overall parameters, which can be derived from small-angle X-ray scattering (SAXS) experiments on macromolecular solutions is the molecular mass (MM) of the solute. In particular, for a monodisperse protein solution, MM of the solute is calculated from the extrapolated scattering intensity at zero angle I(0). Assessing MM by SAXS provides valuable information about the oligomeric state and absence of unspecific aggregation in solution. The value of MM can either be estimated by comparison with a protein standard with a known MM or by determining the absolute scattering intensity using, e.g., water scattering. In both cases, knowledge about the solute concentration and about the partial specific volume of the protein is required. By measuring 13 well characterized globular proteins with MMs ranging from 13.7 to 669 kDa we analyze the sources of possible systematic deviations and assess the accuracy of MM determination using SAXS. The data indicate that all these proteins have approximately the same `effective' value of the partial specific volume of about 0.7425 cm3 g−1. It is shown that both inter-protein and water calibration can be used for molecular mass determination by SAXS and in most cases the errors do not exceed 10%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New developments in the ATSAS program package for small-angle scattering data analysis
Petoukhov, M. V., Franke, D., Shkumatov, A. V., Tria, G., Kikhney, A. G., Gajda, M., Gorba, C., Mertens, H. D. T., Konarev, P. V., & Svergun, D. I. (2012) · Journal of Applied Crystallography · doi:10.1107/s0021889812007662 · Cited by 1,903
Self-citationBiomimetic mineralization of metal-organic frameworks as protective coatings for biomacromolecules
Liang, K., Ricco, R., Doherty, C. M., Styles, M. J., Bell, S., Kirby, N., Mudie, S., Haylock, D., Hill, A. J., Doonan, C. J., et al. (2015) · Nature Communications · doi:10.1038/ncomms8240 · Cited by 1,496
Putnam, C. D., Hammel, M., Hura, G. L., & Tainer, J. A. (2007) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583507004635 · Cited by 1,184
ATSAS 3.0: expanded functionality and new tools for small-angle scattering data analysis
Manalastas-Cantos, K., Konarev, P. V., Hajizadeh, N. R., Kikhney, A. G., Petoukhov, M. V., Molodenskiy, D. S., Panjkovich, A., Mertens, H. D. T., Gruzinov, A., Borges, C., et al. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576720013412 · Cited by 964
Self-citationAccurate assessment of mass, models and resolution by small-angle scattering
Rambo, R. P., & Tainer, J. A. (2013) · Nature · doi:10.1038/nature12070 · Cited by 750
Metadata
- Authors
- Mylonas, E., & Svergun, D. I.
- Venue
- Journal of Applied Crystallography
- Published
- 2007-02-17
- Volume
- 40
- Issue
- s1
- Pages
- s245-s249
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2169620403
- Cited by
- 374
- References
- 0
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of molecular mass determination of proteins in solution by small-angle X-ray scattering. https://app.cochat.ai/papers/10.1107/s002188980700252x
- The paper
- Mylonas, E., & Svergun, D. I. (2007). Accuracy of molecular mass determination of proteins in solution by small-angle X-ray scattering. Journal of Applied Crystallography. https://doi.org/10.1107/s002188980700252x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.