Applications of an amorphous silicon-based area detector for high-resolution, high-sensitivity and fast time-resolved pair distribution function measurements
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The application of a large-area (41 × 41 cm, 2048 × 2048 or 1024 × 1024 pixel) high-sensitivity (detective quantum efficiency > 65%) fast-readout (up to 7.5 or 30 Hz) flat-panel detector based on an amorphous silicon array system to the collection of high-energy X-ray scattering data for quantitative pair distribution function (PDF) analysis is evaluated and discussed. Data were collected over a range of exposure times (0.13 s–7 min) for benchmark PDF samples: crystalline nickel metal and amorphous silica (SiO 2). The high real-space resolution of the resultant PDFs (with Qmax up to ∼40 Å−1) and the high quality of fits to data [RNi(0.13s)= 10.5%,RNi(1.3s)= 6.3%] obtained in short measurement times indicate that this detector is well suited to studies of materials disorder. Further applications of the detector to locate weakly scattering H 2 molecules within the porous Prussian blue system, {\rm Mn}^{\rm II}_{\,3}[Co III(CN)6]2·x H 2, and to follow the in situ reduction of Pt IV O 2 to Pt 0 at 30 Hz, confirm the high sensitivity of the detector and demonstrate a new potential for fast time-resolved studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Warren, Β. E. (1968) · Cited by 7,388
Two-dimensional detector software: From real detector to idealised image or two-theta scan
Hammersley, A. P., Svensson, S. O., Hanfland, M., Fitch, A. N., & Hausermann, D. (1996) · High Pressure Research · doi:10.1080/08957959608201408 · Cited by 4,674 · cited 1×
“The corrected two-dimensional images were integrated within Fit2D, excluding the radial area in which the beamstop arm shadowed the scattered beam, to obtain the one-dimensional powder diffraction pattern (Hammersley et al., 1996).”
MethodUnderneath the Bragg Peaks - Structural Analysis of Complex Materials
(2012) · Pergamon Materials Series · doi:10.1016/c2010-0-66357-7 · Cited by 1,116
Qiu, X., Thompson, J. W., & Billinge, S. J. L. (2004) · Journal of Applied Crystallography · doi:10.1107/s0021889804011744 · Cited by 1,023 · cited 1×
“The PDFs, G(r) = 4 r[ (r) o], where (r) and o are the instantaneous and average densities, were extracted using PDFgetX2 (Qiu et al., 2004), subtracting the contributions from the sample environment and background to the measured diffraction intensities.”
MethodRapid-acquisition pair distribution function (RA-PDF) analysis
Chupas, P. J., Qiu, X., Hanson, J. C., Lee, P. L., Grey, C. P., & Billinge, S. J. L. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889803017564 · Cited by 575 · cited 1×
“…over the traditional scanning approach, based on point-by-point detection, by combining high-energy X-rays (> 60 keV) with imaging plate (IP) area detectors to measure simultaneously the scattered intensity to moderately high values of momentum transfer (Qmax ’ 20–25 Å 1)1 (Chupas et al., 2003).”
BackgroundSelf-citationPDFFIT, a program for full profile structural refinement of the atomic pair distribution function
Proffen, T., & Billinge, S. J. L. (1999) · Journal of Applied Crystallography · doi:10.1107/s0021889899003532 · Cited by 477 · cited 1×
“Refinement of a face-centered cubic structural model for Ni and Pt against G(r) was performed within PDFFIT (Proffen & Billinge, 1999).”
MethodPetkov, V. G., Billinge, S. J. L., Shastri, S. D., & Himmel, B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3436 · Cited by 179
High Real-Space Resolution Measurement of the Local Structure of Ga1−xInxAs Using X-Ray Diffraction
Petkov, V. G., Jeong, I.-K., Chung, J. S., Thorpe, M. F., Kycia, S., & Billinge, S. J. L. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.4089 · Cited by 134 · cited 1×
“…achieved at spallation neutron sources (Hannon, 2005), have only rarely been achieved with X-rays (Petkov, Billinge, Shastri & Himmel, 2000; Petkov et al., 1999; Laaziri et al., 1999), although the data presented here required significantly shorter collection times than previous X-ray or…”
ResultBringing time resolution to EXAFS: recent developments and application to chemical systems
Newton, M. A., Dent, A. J., & Evans, J. (2002) · Chemical Society Reviews · doi:10.1039/b100115a · Cited by 124 · cited 1×
“Two different approaches have been applied to the collection of local structural information using time-resolved EXAFS (extended X-ray absorption fine structure) with time resolutions approaching that presented here: quick EXAFS (QEXAFS) and energy dispersive EXAFS (EDE; Newton et al., 2002).”
MethodMacromolecular crystallography with synchrotron radiation
(1993) · International Journal of Biochemistry · doi:10.1016/0020-711x(93)90368-o · Cited by 53
Cited by
Juhás, P., Davis, T., Farrow, C. L., & Billinge, S. J. L. (2013) · Journal of Applied Crystallography · doi:10.1107/s0021889813005190 · Cited by 1,341
Radioactive Iodine Capture in Silver-Containing Mordenites through Nanoscale Silver Iodide Formation
Chapman, K. W., Chupas, P. J., & Nenoff, T. M. (2010) · Journal of the American Chemical Society · doi:10.1021/ja103110y · Cited by 735
Self-citationReversible magnesium and aluminium ions insertion in cation-deficient anatase TiO2
Koketsu, T., Ma, J., Morgan, B. J., Body, M., Legein, C., Dachraoui, W., Giannini, M., Demortière, A., Salanne, M., Dardoize, F., et al. (2017) · Nature Materials · doi:10.1038/nmat4976 · Cited by 480
Self-citationCompetitive I2 Sorption by Cu-BTC from Humid Gas Streams
Sava, D. F., Chapman, K. W., Rodriguez, M. A., Greathouse, J. A., Crozier, P. S., Zhao, H., Chupas, P. J., & Nenoff, T. M. (2013) · Chemistry of Materials · doi:10.1021/cm401762g · Cited by 363
Self-citationAlayoglu, S., Zavalij, P., Eichhorn, B., Wang, Q., Frenkel, A. I., & Chupas, P. (2009) · ACS Nano · doi:10.1021/nn900242v · Cited by 247
Self-citation
Metadata
- Authors
- Chupas, P. J., Chapman, K. W., & Lee, P. L.
- Venue
- Journal of Applied Crystallography
- Published
- 2007-05-15
- Volume
- 40
- Issue
- 3
- Pages
- 463-470
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1980686121
- Cited by
- 218
- References
- 10
- FWCI
- 5.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.