A wide-angle X-ray fibre diffraction method for quantifying collagen orientation across large tissue areas: application to the human eyeball coat
Open accessAbstract
A quantitative map of collagen fibril orientation across the human eyeball coat, including both the cornea and the sclera, has been obtained using a combination of synchrotron wide-angle X-ray scattering (WAXS) and three-dimensional point mapping. A macromolecular crystallography beamline, in a custom-modified fibre diffraction setup, was used to record the 1.6 nm intermolecular equatorial reflection from fibrillar collagen at 0.5 mm spatial resolution across a flat-mounted human eyeball coat. Fibril orientation, derived as an average measure of the tissue thickness, was quantified by extraction of the azimuthal distribution of WAXS scatter intensity. Vector plots of preferential fibre orientation were remapped onto an idealized eyeball surface using a custom-built numerical algorithm, to obtain a three-dimensional representation of the collagen fibril architecture.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
X-ray scattering has shown that collagen lamellae in the human cornea have preferred orientations: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.
“X-ray scattering has shown that the lamellae have preferred orientations in the human cornea: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [12]
Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.
“Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [12]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- Coudrillier, B., Boote, C., Quigley, H. A. & Nguyen, T. D. (2012). Biomech. Model Mechanobiol. doi:10.1007/s10237-012-0455-y. · DOI
- Maurice, D. M. (1988). The Cornea: Transactions of the World Congress on the Cornea III, edited by H. D. Cavanagh, pp. 187-192. New York: Raven Press.
- Meek, K. M. (2008). Collagen: Structure and Mechanics, edited by P. Fratzl, pp. 359-396. New York: Springer.
Cited by
Sorted by citations
Structural control of corneal transparency, refractive power and dynamics
Meek, K. M., Knupp, C., Lewis, P. N., Morgan, S. R., & Hayes, S. (2025) · Eye · doi:10.1038/s41433-024-02969-7 · Cited by 45 · see citing works
- Authors
- Pijanka, J. K., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C.
- Affiliations
- Cardiff University (GB)
- University of Liverpool (GB)
- Moorfields Eye Hospital NHS Foundation Trust (GB)
- Venue
- Journal of Applied Crystallography
- Published
- 2013-09-18
- Volume
- 46
- Issue
- 5
- Pages
- 1481-1489
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2144605396
- Cited by
- 38
- References
- 1
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 9 · 2017: 4 · 2015: 3 · 2014: 2
- FWCI
- 0.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Applied Crystallography (publishedVersion, cc-by)
- ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
- Funders
- National Institute for Health and Care Research
- Moorfields Eye Hospital NHS Foundation Trust
- Topics
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Physical Sciences › Materials Science › Materials Chemistry › X-ray Diffraction in Crystallography
- Keywords
- collagen fibril orientation, wide-angle X-ray scattering, fiber diffraction, cornea, sclera, fibrillar collagen, azimuthal distribution, human eye
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review