Cited by 38Collagen: Extraction and CharacterizationAdvanced X-ray Imaging TechniquesX-ray Diffraction in Crystallography

A wide-angle X-ray fibre diffraction method for quantifying collagen orientation across large tissue areas: application to the human eyeball coat

Open access
Pijanka, Jacek Klaudiusz, Abass, Ahmed, Sorensen, Thomas, Elsheikh, Ahmed, Boote, Craig·2013·Journal of Applied Crystallography

Abstract

A quantitative map of collagen fibril orientation across the human eyeball coat, including both the cornea and the sclera, has been obtained using a combination of synchrotron wide-angle X-ray scattering (WAXS) and three-dimensional point mapping. A macromolecular crystallography beamline, in a custom-modified fibre diffraction setup, was used to record the 1.6 nm intermolecular equatorial reflection from fibrillar collagen at 0.5 mm spatial resolution across a flat-mounted human eyeball coat. Fibril orientation, derived as an average measure of the tissue thickness, was quantified by extraction of the azimuthal distribution of WAXS scatter intensity. Vector plots of preferential fibre orientation were remapped onto an idealized eyeball surface using a custom-built numerical algorithm, to obtain a three-dimensional representation of the collagen fibril architecture.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0021889813022358

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • X-ray scattering has shown that collagen lamellae in the human cornea have preferred orientations: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.

    “X-ray scattering has shown that the lamellae have preferred orientations in the human cornea: inferior-superior and nasal-temporal in the central cornea and circumferential at the limbus.”
  • Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.

    “Throughout the optical zone, there is a preference for lamellae to run in the inferior-superior and temporal-nasal directions.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. Coudrillier, B., Boote, C., Quigley, H. A. & Nguyen, T. D. (2012). Biomech. Model Mechanobiol. doi:10.1007/s10237-012-0455-y. · DOI
  2. Maurice, D. M. (1988). The Cornea: Transactions of the World Congress on the Cornea III, edited by H. D. Cavanagh, pp. 187-192. New York: Raven Press.
  3. Meek, K. M. (2008). Collagen: Structure and Mechanics, edited by P. Fratzl, pp. 359-396. New York: Springer.

Cited by

Sorted by citations

Authors
Pijanka, J. K., Abass, A., Sorensen, T., Elsheikh, A., & Boote, C.
Affiliations
  • Cardiff University (GB)
  • University of Liverpool (GB)
  • Moorfields Eye Hospital NHS Foundation Trust (GB)
Venue
Journal of Applied Crystallography
Published
2013-09-18
Volume
46
Issue
5
Pages
1481-1489
ISSN
0021-8898 (ISSN-L)
OpenAlex
W2144605396
Cited by
38
References
1
Citations by year
2026: 2 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 5 · 2018: 9 · 2017: 4 · 2015: 3 · 2014: 2
FWCI
0.64
Type
journal article
Language
en
Open access
Locations
  • Journal of Applied Crystallography (publishedVersion, cc-by)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Funders
  • National Institute for Health and Care Research
  • Moorfields Eye Hospital NHS Foundation Trust
Topics
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Materials Science › Materials Chemistry › X-ray Diffraction in Crystallography
Keywords
collagen fibril orientation, wide-angle X-ray scattering, fiber diffraction, cornea, sclera, fibrillar collagen, azimuthal distribution, human eye

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review