The DOI matches its Crossref record.
Use of the Voigt function in a single-line method for the analysis of X-ray diffraction line broadening
Abstract
The use of the Voigt function for the analysis of the integral breadths of broadened X-ray diffraction line profiles forms the basis of a rapid and powerful single-line method of crystallite-size and strain determination which is easy to apply. To avoid graphical methods or interpolation from tables, empirical formulae of high accuracy are used and an estimation of errors is presented, including the influence of line-profile asymmetry. The method is applied to four practical cases of size-strain broadening: (i) cold-worked nickel, (ii) a nitrided steel, (iii) an electrodeposited nickel layer and (iv) a liquid-quenched AlSi alloy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Extended pseudo-Voigt function for approximating the Voigt profile
Ida, T., Ando, M., & Toraya, H. (2000) · Journal of Applied Crystallography · doi:10.1107/s0021889800010219 · Cited by 306
Ascarelli, P., Contini, V., & Giorgi, R. (2002) · Journal of Applied Physics · doi:10.1063/1.1453495 · Cited by 63
Satoh, K., Sato, S., Yamanaka, K., Suzuki, S., Chiba, A., & Wagatsuma, K. (2016) · High Temperature Materials and Processes · doi:10.1515/htmp-2015-0039 · Cited by 5
Metadata
- Authors
- de Keijser, T. H., Langford, J. I., Mittemeijer, E. J., & Vogels, A. B. P.
- Venue
- Journal of Applied Crystallography
- Published
- 1982-06-01
- Volume
- 15
- Issue
- 3
- Pages
- 308-314
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2065028460
- Cited by
- 1,209
- References
- 0
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of the Voigt function in a single-line method for the analysis of X-ray diffraction line broadening. https://app.cochat.ai/papers/10.1107/s0021889882012035
- The paper
- de Keijser, T. H., Langford, J. I., Mittemeijer, E. J., & Vogels, A. B. P. (1982). Use of the Voigt function in a single-line method for the analysis of X-ray diffraction line broadening. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889882012035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.