A fundamental parameters approach to X-ray line-profile fitting
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A convolution approach to X-ray powder line-profile fitting is developed in which the line shape is synthesized from the Cu Kα emission profile, the dimensions of the diffractometer and the physical variables of the specimen. In addition to the integrated intensities and 2 θ positions of the line profiles, the parameters that may be fitted include the receiving-slit width, the receiving-slit length, the X-ray-source size, the angle of divergence of the incident beam, the X-ray attenuation coefficient of the specimen and the crystallite size. This is a self-consistent approach to fitting as the instrumental parameters are usually known by direct measurement. To minimize correlation between refined instrumental parameters, profiles at high and low 2 θ values should be fitted simultaneously. The Cu Kα emission profile used in this work is based on recent monolithic double-crystal spectrometer measurements that have identified a doublet structure in both the Kα 1 and Kα 2 components. Fast and accurate convolution procedures have been developed and a mixture of multilinear regression and Gauss–Newton non-linear least squares with numerical differentials is used for fitting the profiles. The method is evaluated by fitting powder diffraction data from well crystallized specimens of MgO and Y 3 Al 5 O 12 (YAG). Testing has also been carried out by examining the changes in the fitted values after altering various instrumental parameters (e.g. receiving-slit width, detector defocus, receiving-slit length and inclusion of a monochromator).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Klug, H. P., & Alexander, L. (1954) · CERN Document Server (European Organization for Nuclear Research) · Cited by 4,224
X rays in Atomic and Nuclear Physics
Dyson, N. A., & Smith, W. W. (1974) · Physics Today · doi:10.1063/1.3128695 · Cited by 74
Cited by
Baikie, T., Fang, Y., Kadro, J. M., Schreyer, M., Wei, F., Mhaisalkar, S. G., Graetzel, M., & White, T. J. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta10518k · Cited by 2,534
Coelho, A. A. (2018) · Journal of Applied Crystallography · doi:10.1107/s1600576718000183 · Cited by 2,510
Self-citationRodriguez-Blanco, J. D., Shaw, S., & Benning, L. G. (2011) · Nanoscale · doi:10.1039/c0nr00589d · Cited by 1,141
Cerium oxide nanoparticles: Size-selective formation and structure analysis
Zhang, F., Chan, S.-W., Spanier, J. E., Apak, E., Jin, Q., Robinson, R. D., & Herman, I. P. (2002) · Applied Physics Letters · doi:10.1063/1.1430502 · Cited by 682
Lead-Free MA2CuClxBr4–x Hybrid Perovskites
Cortecchia, D., Dewi, H. A., Yin, J., Bruno, A., Chen, S., Baikie, T., Boix, P. P., Grätzel, M., Mhaisalkar, S., Soci, C., et al. (2016) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.5b01896 · Cited by 574
Metadata
- Authors
- Cheary, R. W., & Coelho, A.
- Venue
- Journal of Applied Crystallography
- Published
- 1992-04-01
- Volume
- 25
- Issue
- 2
- Pages
- 109-121
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1973518565
- Cited by
- 1,660
- References
- 3
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.