CoChat

Structure-factor analysis of femtosecond microdiffraction patterns from protein nanocrystals

Open access
Kirian, Richard A., White, Thomas A., Holton, James M., Chapman, Henry N., Fromme, Petra, Barty, Anton, Lomb, Lukas, Aquila, Andrew, Maia, Filipe R. N. C., Martin, Andrew V., Fromme, Raimund, Wang, Xiaoyu, Hunter, Mark S., Schmidt, Kevin E., Spence, John C. H. · 2011 · Acta Crystallographica Section A Foundations of Crystallography
Cited by 141

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A complete set of structure factors has been extracted from hundreds of thousands of femtosecond single-shot X-ray microdiffraction patterns taken from randomly oriented nanocrystals. The method of Monte Carlo integration over crystallite size and orientation was applied to experimental data from Photosystem I nanocrystals. This arrives at structure factors from many partial reflections without prior knowledge of the particle-size distribution. The data were collected at the Linac Coherent Light Source (the first hard-X-ray laser user facility), to which was fitted a hydrated protein nanocrystal injector jet, according to the method of serial crystallography. The data are single 'still' diffraction snapshots, each from a different nanocrystal with sizes ranging between 100 nm and 2 µm, so the angular width of Bragg peaks was dominated by crystal-size effects. These results were compared with single-crystal data recorded from large crystals of Photosystem I at the Advanced Light Source and the quality of the data was found to be similar. The implications for improving the efficiency of data collection by allowing the use of very small crystals, for radiation-damage reduction and for time-resolved diffraction studies at room temperature are discussed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0108767310050981

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • First lasing and operation of an ångstrom-wavelength free-electron laser

    Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167 · cited 7×

    “In the experimental setup at the ‘CFEL–ASG multi-purpose’ (CAMP) end-station (Strüder et al., 2010) on the Atomic, Molecular and Optical Science (AMO) beamline (Bozek, 2009), single-crystal diffraction data were collected from a stream of nanocrystals carried in a continuous liquid water jet that flows, in vacuum, ac…”
    MethodInfluential
  • Potential for biomolecular imaging with femtosecond X-ray pulses

    Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×

    “It has been proposed that femtosecond X-ray pulses can be used to out-run damage processes, when using single pulses so brief that they terminate before the onset of significant radiation damage (Neutze et al., 2000; Solem, 1986).”
    Background
  • Imaging biological specimens with high-intensity soft x rays

    Solem, J. C. (1986) · Journal of the Optical Society of America B · doi:10.1364/josab.3.001551 · Cited by 92 · cited 1×

    “It has been proposed that femtosecond X-ray pulses can be used to out-run damage processes, when using single pulses so brief that they terminate before the onset of significant radiation damage (Neutze et al., 2000; Solem, 1986).”
    Background

Show all 3 references

Cited by

See all 141

Metadata

Authors
Kirian, R. A., White, T. A., Holton, J. M., Chapman, H. N., Fromme, P., Barty, A., Lomb, L., Aquila, A., Maia, F. R. N. C., Martin, A. V., Fromme, R., Wang, X., Hunter, M. S., Schmidt, K. E., & Spence, J. C. H.
Venue
Acta Crystallographica Section A Foundations of Crystallography
Published
2011-02-16
Volume
67
Issue
2
Pages
131-140
ISSN
0108-7673 (ISSN-L)
OpenAlex
W2047189595
Cited by
141
References
3
FWCI
8.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Structure-factor analysis of femtosecond microdiffraction patterns from protein nanocrystals. https://app.cochat.ai/papers/10.1107/s0108767310050981
The paper
Kirian, R. A., White, T. A., Holton, J. M., Chapman, H. N., Fromme, P., Barty, A., Lomb, L., Aquila, A., Maia, F. R. N. C., Martin, A. V., Fromme, R., Wang, X., Hunter, M. S., Schmidt, K. E., & Spence, J. C. H. (2011). Structure-factor analysis of femtosecond microdiffraction patterns from protein nanocrystals. Acta Crystallographica Section A Foundations of Crystallography. https://doi.org/10.1107/s0108767310050981

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.