CoChat

Choice of data-collection parameters based on statistic modelling

Popov, Alexander N., Bourenkov, Gleb P. · 2003 · Acta Crystallographica Section D Biological Crystallography
Cited by 112

The DOI matches its Crossref record.

Abstract

A new method and the software program BEST for optimal planning of X-ray data collection from protein crystals using the rotation method are presented. From one or a few initial diffraction images, BEST estimates the statistical characteristics of the data set for different combinations of data-collection parameters and suggests the most optimal ones. The anisotropy in diffraction and the permitted width of oscillation without spatially overlapping reflections are taken into account. According to the option chosen, the optimal set of parameters provides a given average signal-to-noise ratio at a given resolution either in the shortest time or with the minimum total radiation dose. BEST has been successfully used at the protein crystallography beamlines at DORIS (DESY). The software proved to be extremely useful in using the available data-collection time in the most efficient way.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0907444903008163

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 112

Metadata

Authors
Popov, A. N., & Bourenkov, G. P.
Venue
Acta Crystallographica Section D Biological Crystallography
Published
2003-06-27
Volume
59
Issue
7
Pages
1145-1153
ISSN
0907-4449 (ISSN-L)
OpenAlex
W2027797186
Cited by
112
References
0
FWCI
2.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Choice of data-collection parameters based on statistic modelling. https://app.cochat.ai/papers/10.1107/s0907444903008163
The paper
Popov, A. N., & Bourenkov, G. P. (2003). Choice of data-collection parameters based on statistic modelling. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s0907444903008163

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.