The DOI matches its Crossref record.
The minimum crystal size needed for a complete diffraction data set
Open accessAbstract
In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Native structure of photosystem II at 1.95 Å resolution viewed by femtosecond X-ray pulses
Suga, M., Akita, F., Hirata, K., Ueno, G., Murakami, H., Nakajima, Y., Shimizu, T., Yamashita, K., Yamamoto, M., Ago, H., et al. (2015) · Nature · doi:10.1038/nature13991 · Cited by 1,192
High-Resolution Protein Structure Determination by Serial Femtosecond Crystallography
Boutet, S., Lomb, L., Williams, G. J., Barends, T. R. M., Aquila, A., Doak, R. B., Weierstall, U., DePonte, D. P., Steinbrener, J., Shoeman, R. L., et al. (2012) · Science · doi:10.1126/science.1217737 · Cited by 857
Radiation damage in macromolecular crystallography: what is it and why should we care?
Garman, E. F. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910008656 · Cited by 366
Room-temperature macromolecular serial crystallography using synchrotron radiation
Stellato, F., Oberthür, D., Liang, M., Bean, R., Gati, C., Yefanov, O., Barty, A., Burkhardt, A., Fischer, P., Galli, L., et al. (2014) · IUCrJ · doi:10.1107/s2052252514010070 · Cited by 256
Determination of damage-free crystal structure of an X-ray–sensitive protein using an XFEL
Hirata, K., Shinzawa-Itoh, K., Yano, N., Takemura, S., Kato, K., Hatanaka, M., Muramoto, K., Kawahara, T., Tsukihara, T., Yamashita, E., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2962 · Cited by 253
Metadata
- Authors
- Holton, J. M., & Frankel, K. A.
- Venue
- Acta Crystallographica Section D Biological Crystallography
- Published
- 2010-03-24
- Volume
- 66
- Issue
- 4
- Pages
- 393-408
- ISSN
- 0907-4449 (ISSN-L)
- OpenAlex
- W2133254275
- Cited by
- 189
- References
- 0
- FWCI
- 6.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The minimum crystal size needed for a complete diffraction data set. https://app.cochat.ai/papers/10.1107/s0907444910007262
- The paper
- Holton, J. M., & Frankel, K. A. (2010). The minimum crystal size needed for a complete diffraction data set. Acta Crystallographica Section D Biological Crystallography. https://doi.org/10.1107/s0907444910007262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.