On the use of CCD area detectors for high-resolution specular X-ray reflectivity
Open accessThe DOI matches its Crossref record.
Abstract
The use and application of charge coupled device (CCD) area detectors for high-resolution specular X-ray reflectivity is discussed. Direct comparison of high-resolution specular X-ray reflectivity data measured with CCD area detectors and traditional X-ray scintillator ('point') detectors demonstrates that the use of CCD detectors leads to a substantial (approximately 30-fold) reduction in data acquisition rates because of the elimination of the need to scan the sample to distinguish signal from background. The angular resolution with a CCD detector is also improved by a factor of approximately 3. The ability to probe the large dynamic range inherent to high-resolution X-ray reflectivity data in the specular reflection geometry was demonstrated with measurements of the orthoclase (001)- and alpha-Al2O3 (012)-water interfaces, with measured reflectivity signals varying by a factor of approximately 10(6) without the use of any beam attenuators. Statistical errors in the reflectivity signal are also derived and directly compared with the repeatability of the measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Simultaneous inner- and outer-sphere arsenate adsorption on corundum and hematite
Catalano, J. G., Park, C., Fenter, P., & Zhang, Z. (2008) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2008.02.013 · Cited by 245
Self-citationStern Layer Structure and Energetics at Mica–Water Interfaces
Bourg, I. C., Lee, S. S., Fenter, P., & Tournassat, C. (2017) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b01828 · Cited by 165
“…(for Li, Na, K, and CsCl experiments) or 17 keV (for the RbCl experiment)] reflected from the mica surface was collected using an X-ray CCD detector 79 as a function of momentum transfer q , defined as q = 4πsin(2θ/2)/λ where 2θ is the angle between the incident and reflected X-ray beams and λ is…”
Self-citationHydrated Cation Speciation at the Muscovite (001)−Water Interface
Lee, S. S., Fenter, P., Park, C., Sturchio, N. C., & Nagy, K. L. (2010) · Langmuir · doi:10.1021/la1032866 · Cited by 147
Self-citationLee, S. S., Fenter, P., Nagy, K. L., & Sturchio, N. C. (2012) · Langmuir · doi:10.1021/la300032h · Cited by 145
Self-citationPark, C., Fenter, P. A., Sturchio, N. C., & Nagy, K. L. (2008) · Langmuir · doi:10.1021/la802446m · Cited by 62
Self-citationTermination and hydration of forsteritic olivine (0 1 0) surface
Yan, H., Park, C., Ahn, G., Hong, S., Keane, D. T., Kenney-Benson, C., Chow, P., Xiao, Y., & Shen, G. (2014) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2014.09.005 · Cited by 16
Self-citation
Metadata
- Authors
- Fenter, P., Catalano, J. G., Park, C., & Zhang, Z.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2006-06-15
- Volume
- 13
- Issue
- 4
- Pages
- 293-303
- ISSN
- 0909-0495 (ISSN-L)
- OpenAlex
- W2069218151
- Cited by
- 52
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.