The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: the microfocus endstation
Open accessAbstract
The P03 beamline, also called the microfocus and nanofocus X-ray scattering (MiNaXS) beamline, exploits the excellent photon beam properties of the low-emittance source PETRA III to provide a microfocused/nanofocused beam with ultra-high intensity for time-resolved X-ray scattering experiments. The beamline has been designed to perform X-ray scattering in both transmission and reflection geometries. The microfocus endstation started user operation in May 2011. An overview of the beamline status and of some representative results highlighting the performance of the microfocus endstation at MiNaXS are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A SAXS/WAXS/GISAXS Beamline with Multilayer Monochromator
Hexemer, A., Bras, W., Glossinger, J., Schaible, E., Gann, E., Kirian, R., MacDowell, A., Church, M., Rude, B., & Padmore, H. (2010) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/247/1/012007 · Cited by 540
Real-Time Monitoring of Growing Nanoparticles
Renaud, G., Lazzari, R., Revenant, C., Barbier, A., Noblet, M., Ulrich, O., Leroy, F., Jupille, J., Borensztein, Y., Henry, C. R., et al. (2003) · Science · doi:10.1126/science.1082146 · Cited by 378
Müller-Buschbaum, P. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1869-2 · Cited by 357
Self-citationMetal‐Polymer Nanocomposites for Functional Applications
Faupel, F., Zaporojtchenko, V., Strunskus, T., & Elbahri, M. (2010) · Advanced Engineering Materials · doi:10.1002/adem.201000231 · Cited by 260
Biopolymer Microparticle and Nanoparticle Formation within a Microfluidic Device
Rondeau, E., & Cooper-White, J. J. (2008) · Langmuir · doi:10.1021/la703339u · Cited by 110
X-ray microfocussing combined with microfluidics for on-chip X-ray scattering measurements
Barrett, R., Fauçon, M., Lopez, J., Cristobal, G., Destremaut, F., Dodge, A., Guillot, P., Laval, P., Masselon, C., & Salmon, J. (2006) · Lab on a Chip · doi:10.1039/b517055a · Cited by 80
In situobservation of cluster formation during nanoparticle solution casting on a colloidal film
Roth, S. V., Herzog, G., Körstgens, V., Buffet, A., Schwartzkopf, M., Perlich, J., Kashem, M. M. A., Döhrmann, R., Gehrke, R., Rothkirch, A., et al. (2011) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/23/25/254208 · Cited by 75
Self-citationA two-dimensional waveguide beam for X-ray nanodiffraction
Krywka, C., Neubauer, H., Priebe, M., Salditt, T., Kečkéš, J., Buffet, A., Roth, S. V., Döhrmann, R., & Mueller, M. G. (2011) · Journal of Applied Crystallography · doi:10.1107/s0021889811049132 · Cited by 72
Self-citationMicrofluidics of soft matter investigated by small-angle X-ray scattering
Otten, A., Köster, S., Struth, B., Snigirev, A. A., & Pfohl, T. (2005) · Journal of Synchrotron Radiation · doi:10.1107/s0909049505013580 · Cited by 72
Tsuruta, H., Brennan, S., Rek, Z. U., Irving, T. C., Tompkins, W. H., & Hodgson, K. O. (1998) · Journal of Applied Crystallography · doi:10.1107/s0021889898002702 · Cited by 52
Cited by
Mittal, N., Ansari, F., Gowda.V, K., Brouzet, C., Chen, P., Larsson, P. T., Roth, S. V., Lundell, F., Wågberg, L., Kotov, N. A., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b01084 · Cited by 507
Self-citationAdvanced grazing-incidence techniques for modern soft-matter materials analysis
Hexemer, A., & Müller-Buschbaum, P. (2015) · IUCrJ · doi:10.1107/s2052252514024178 · Cited by 263
Self-citationHaas, S., Sun, X., Conceição, A. L. C., Horbach, J., & Pfeffer, S. (2023) · Journal of Synchrotron Radiation · doi:10.1107/s1600577523008603 · Cited by 43
Metadata
- Authors
- Buffet, A., Rothkirch, A., Döhrmann, R., Körstgens, V., Abul Kashem, M. M., Perlich, J., Herzog, G., Schwartzkopf, M., Gehrke, R., Müller-Buschbaum, P., & Roth, S. V.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2012-05-10
- Volume
- 19
- Issue
- 4
- Pages
- 647-653
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2117154563
- Cited by
- 351
- References
- 13
- FWCI
- 20.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: the microfocus endstation. https://app.cochat.ai/papers/10.1107/s0909049512016895
- The paper
- Buffet, A., Rothkirch, A., Döhrmann, R., Körstgens, V., Abul Kashem, M. M., Perlich, J., Herzog, G., Schwartzkopf, M., Gehrke, R., Müller-Buschbaum, P., & Roth, S. V. (2012). P03, the microfocus and nanofocus X-ray scattering (MiNaXS) beamline of the PETRA III storage ring: the microfocus endstation. Journal of Synchrotron Radiation. https://doi.org/10.1107/s0909049512016895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.