A hard X-ray nanoprobe beamline for nanoscale microscopy
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The Hard X-ray Nanoprobe Beamline (or Nanoprobe Beamline) is an X-ray microscopy facility incorporating diffraction, fluorescence and full-field imaging capabilities designed and operated by the Center for Nanoscale Materials and the Advanced Photon Source at Sector 26 of the Advanced Photon Source at Argonne National Laboratory. This facility was constructed to probe the nanoscale structure of biological, environmental and material sciences samples. The beamline provides intense focused X-rays to the Hard X-ray Nanoprobe (or Nanoprobe) which incorporates Fresnel zone plate optics and a precision laser sensing and control system. The beamline operates over X-ray energies from 3 to 30 keV, enabling studies of most elements in the periodic table, with a particular emphasis on imaging transition metals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Structure of the Potassium Channel: Molecular Basis of K + Conduction and Selectivity
Doyle, D. A., Cabral, J. M., Pfuetzner, R. A., Kuo, A., Gulbis, J. M., Cohen, S. L., Chait, B. T., & MacKinnon, R. (1998) · Science · doi:10.1126/science.280.5360.69 · Cited by 6,807 · cited 1×
“…the technology and methods developed for synchrotron X-ray research have contributed significantly to our understanding of structural biology (Doyle et al., 1998; Schotte et al., 2003), materials science (Srajer et al., 2006; Poulsen et al., 2001; Banhart et al., 2001) and condensed-matter…”
MethodDynamical Diffraction of X Rays by Perfect Crystals
BATTERMAN, B. W., & COLE, H. (1964) · Reviews of Modern Physics · doi:10.1103/revmodphys.36.681 · Cited by 1,438 · cited 1×
“The DCM (Oxford Danfysik Model S1614), located 63.2 m from the X-ray source, is used for high-energy-resolution imaging ( E/E = 1.7 10 4) (Batterman & Cole, 1964).”
MethodInfluentialWatching a Protein as it Functions with 150-ps Time-Resolved X-ray Crystallography
Schotte, F., Lim, M., Jackson, T. A., Smirnov, A. V., Soman, J., Olson, J. S., Phillips, G. N., Wulff, M., & Anfinrud, P. A. (2003) · Science · doi:10.1126/science.1078797 · Cited by 752 · cited 1×
“…and methods developed for synchrotron X-ray research have contributed significantly to our understanding of structural biology (Doyle et al., 1998; Schotte et al., 2003), materials science (Srajer et al., 2006; Poulsen et al., 2001; Banhart et al., 2001) and condensed-matter physics (Reichert et…”
MethodTkachuk, A., Duewer, F., Cui, H., Feser, M., Wang, S., & Yun, W. (2007) · Zeitschrift für Kristallographie - Crystalline Materials · doi:10.1524/zkri.2007.222.11.650 · Cited by 207 · cited 1×
“X-rays diffracted by the sample are collected by a zone plate which magnifies and focuses the image onto imaging optics and a CCD camera located at the end of the beamline (Tkachuk et al., 2007).”
BackgroundEllipsoidal and parabolic glass capillaries as condensers for x-ray microscopes
Zeng, X., Duewer, F., Feser, M., Huang, C., Lyon, A., Tkachuk, A., & Yun, W. (2008) · Applied Optics · doi:10.1364/ao.47.002376 · Cited by 100 · cited 1×
“For full-field imaging and nanotomography the X-ray beam is directed onto a capillary condenser which focuses the X-rays onto the sample (Zeng et al., 2008).”
BackgroundAdvances in nanomagnetism via X-ray techniques
Srajer, G., Lewis, L. H., Bader, S. D., Epstein, A. J., Fadley, C. S., Fullerton, E. E., Hoffmann, A., Kortright, J. B., Krishnan, K. M., Majetich, S. A., et al. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.06.033 · Cited by 94 · cited 1×
“…X-ray research have contributed significantly to our understanding of structural biology (Doyle et al., 1998; Schotte et al., 2003), materials science (Srajer et al., 2006; Poulsen et al., 2001; Banhart et al., 2001) and condensed-matter physics (Reichert et al., 2000; Alagna et al., 1998).”
BackgroundThe history and future of X-ray microscopy
Kirz, J., & Jacobsen, C. J. (2009) · Journal of Physics Conference Series · doi:10.1088/1742-6596/186/1/012001 · Cited by 94 · cited 1×
“Hard X-ray microscopy and imaging have made major additions to our knowledge in these areas, but until recently were typically limited to spatial resolutions of only hundreds of nanometers (Kirz & Jacobsen, 2009).”
BackgroundShu, D., Maser, J. M., Holt, M. V., Winarski, R. P., Preissner, C., Smolyanitskiy, A., Lai, B. C. H., Vogt, S., & Stephenson, G. B. (2007) · AIP conference proceedings · doi:10.1063/1.2436307 · Cited by 26 · cited 2×
“5, is a combination scanning probe and full-field imaging microscope that incorporates fluorescence mapping, nanodiffraction and transmission imaging with absorption and phase contrast (Shu et al., 2005, 2007).”
BackgroundMethodSelf-citation
Cited by
Maire, E., & Withers, P. J. (2014) · International Materials Reviews · doi:10.1179/1743280413y.0000000023 · Cited by 1,374
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
Facet-dependent active sites of a single Cu2O particle photocatalyst for CO2 reduction to methanol
Wu, Y. A., McNulty, I., Liu, C., Lau, K. C., Liu, Q., Paulikas, A. P., Sun, C.-J., Cai, Z., Guest, J. R., Ren, Y., et al. (2019) · Nature Energy · doi:10.1038/s41560-019-0490-3 · Cited by 552
Self-citationA review of predictive nonlinear theories for multiscale modeling of heterogeneous materials
Matouš, K., Geers, M. G. D., Kouznetsova, V. G., & Gillman, A. (2017) · Journal of Computational Physics · doi:10.1016/j.jcp.2016.10.070 · Cited by 493
ID16B: a hard X-ray nanoprobe beamline at the ESRF for nano-analysis
Martínez-Criado, G., Villanova, J., Tucoulou, R., Salomon, D., Suuronen, J.-P., Labouré, S., Guilloud, C., Valls, V., Barrett, R., Gagliardini, E., et al. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515019839 · Cited by 263
Nanoscale Hard X-Ray Microscopy Methods for Materials Studies
Holt, M., Harder, R., Winarski, R., & Rose, V. (2013) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-071312-121654 · Cited by 183
Self-citationVitol, E. A., Rozhkova, E. A., Rose, V., Stripe, B. D., Young, N. R., Cohen, E. E. W., Leoni, L., & Novosad, V. (2014) · Advanced Materials Interfaces · doi:10.1002/admi.201400182 · Cited by 24
Self-citation
Metadata
- Authors
- Winarski, R. P., Holt, M. V., Rose, V., Fuesz, P., Carbaugh, D., Benson, C., Shu, D., Kline, D., Stephenson, G. B., McNulty, I., & Maser, J.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2012-09-05
- Volume
- 19
- Issue
- 6
- Pages
- 1056-1060
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2168999192
- Cited by
- 188
- References
- 8
- FWCI
- 13.96
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.