The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination
Open accessAbstract
The quality of diffraction data obtained using silver and molybdenum microsources has been compared for six model compounds with a wide range of absorption factors. The experiments were performed on two 30 W air-cooled Incoatec IµS microfocus sources with multilayer optics mounted on a Bruker D8 goniometer with a SMART APEX II CCD detector. All data were analysed, processed and refined using standard Bruker software. The results show that Ag K α radiation can be beneficial when heavy elements are involved. A numerical absorption correction based on the positions and indices of the crystal faces is shown to be of limited use for the highly focused microsource beams, presumably because the assumption that the crystal is completely bathed in a (top-hat profile) beam of uniform intensity is no longer valid. Fortunately the empirical corrections implemented in SADABS , although originally intended as a correction for absorption, also correct rather well for the variations in the effective volume of the crystal irradiated. In three of the cases studied (two Ag and one Mo) the final SHELXL R 1 against all data after application of empirical corrections implemented in SADABS was below 1%. Since such corrections are designed to optimize the agreement of the intensities of equivalent reflections with different paths through the crystal but the same Bragg 2θ angles, a further correction is required for the 2θ dependence of the absorption. For this, SADABS uses the transmission factor of a spherical crystal with a user-defined value of μ r (where μ is the linear absorption coefficient and r is the effective radius of the crystal); the best results are obtained when r is biased towards the smallest crystal dimension. The results presented here suggest that the IUCr publication requirement that a numerical absorption correction must be applied for strongly absorbing crystals is in need of revision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Figure 5 χ2 after applying corrections and deriving the error model for crystal 2. Ag (left) and Mo (right) radiation. χ2 = mean{N∑(I − 〈I〉)2/(N − 1)∑[s.u.2(I)]} (N equivalents).](https://figures.cochat.ai/paper-figures/771f45ec23644c3d9bbb2defadb3cc2a/comparison-of-silver-and-molybdenum-microfocus-x-ray-sources-for-single-crystal-figure-5.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“We normalized the CD signal amplitude on the basis of the UV/Vis absorption and calculated the ee using the calibration procedure described in section S9 (57–62).”
From Origin of biological homochirality by crystallization of an RNA precursor on a magnetic surface (2023) · cites this paper as [59]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sheldrick, G. M. (2008) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767307043930 · Cited by 87,804
Self-citationAn empirical correction for absorption anisotropy
Blessing, R. H. (1995) · Acta Crystallographica Section A Foundations of Crystallography · doi:10.1107/s0108767394005726 · Cited by 7,928
A semi-empirical method of absorption correction
North, A. C. T., Phillips, D. C., & Mathews, F. S. (1968) · Acta Crystallographica Section A · doi:10.1107/s0567739468000707 · Cited by 7,467
How good are my data and what is the resolution?
Evans, P. R., & Murshudov, G. N. (2013) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444913000061 · Cited by 4,697
ShelXle: a Qt graphical user interface for SHELXL
Hübschle, C. B., Sheldrick, G. M., & Dittrich, B. (2011) · Journal of Applied Crystallography · doi:10.1107/s0021889811043202 · Cited by 3,810
Self-citationIntegration, scaling, space-group assignment and post-refinement
Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047374 · Cited by 2,528
Significance tests on the crystallographic R factor
Hamilton, W. C. (1965) · Acta Crystallographica · doi:10.1107/s0365110x65001081 · Cited by 1,952
Outlier Treatment in Data Merging
Blessing, R. H. (1997) · Journal of Applied Crystallography · doi:10.1107/s0021889896014628 · Cited by 1,338
Becker, P. J., & Coppens, P. (1974) · Acta Crystallographica Section A · doi:10.1107/s0567739474000337 · Cited by 1,054
Global indicators of X-ray data quality
Weiss, M. S. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889800018227 · Cited by 684
Cited by
Crystal structure refinement with SHELXL
Sheldrick, G. M. (2015) · Acta Crystallographica Section C Structural Chemistry · doi:10.1107/s2053229614024218 · Cited by 43,982
Self-citationEnantioselective photochemistry through Lewis acid–catalyzed triplet energy transfer
Blum, T. R., Miller, Z. D., Bates, D. M., Guzei, I. A., & Yoon, T. P. (2016) · Science · doi:10.1126/science.aai8228 · Cited by 420
Barely porous organic cages for hydrogen isotope separation
Liu, M., Zhang, L., Little, M. A., Kapil, V., Ceriotti, M., Yang, S., Ding, L., Holden, D. L., Balderas-Xicohténcatl, R., He, D., et al. (2019) · Science · doi:10.1126/science.aax7427 · Cited by 399
Accurate crystal structures and chemical properties from NoSpherA2
Kleemiss, F., Dolomanov, O. V., Bodensteiner, M., Peyerimhoff, N., Midgley, L., Bourhis, L. J., Genoni, A., Malaspina, L. A., Jayatilaka, D., Spencer, J. L., et al. (2021) · Chemical Science · doi:10.1039/d0sc05526c · Cited by 390
Carrington, E. J., McAnally, C. A., Fletcher, A. J., Thompson, S. P., Warren, M., & Brammer, L. (2017) · Nature Chemistry · doi:10.1038/nchem.2747 · Cited by 366
Metadata
- Authors
- Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D.
- Affiliations
- University of Göttingen (DE)
- Corresponding author
- Stalke, Dietmar
- Venue
- Journal of Applied Crystallography
- Published
- 2015-01-30
- Volume
- 48
- Issue
- 1
- Pages
- 3-10
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- PMC
- PMC4453166
- OpenAlex
- W2101547779
- Cited by
- 4,983
- References
- 35
- Citations by year
- 2026: 512 · 2025: 673 · 2024: 690 · 2023: 754 · 2022: 546 · 2021: 476 · 2020: 426 · 2019: 317 · 2018: 267 · 2017: 175 · 2016: 86 · 2015: 59
- FWCI
- 48.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/2.0/uk/legalcode (vor)
- creativecommons.org/licenses/by/2.0/uk/legalcode (tdm)
- Locations
- Journal of Applied Crystallography (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- GoeScholar The Publication Server of the Georg-August-Universität Göttingen (Georg-August-Universität Göttingen) (submittedVersion, cc-by)
- GRO (submittedVersion, cc-by)
- Funders
- National Research Foundation (DNRF93)
- Danmarks Grundforskningsfond (DNRF‐93)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › X-ray Diffraction in Crystallography
- Physical Sciences › Chemistry › Inorganic Chemistry › Crystal structures of chemical compounds
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Structural Biology › Enzyme Structure and Function
- Keywords
- microfocus X-ray source, single-crystal structure determination, absorption correction, multilayer optics, transmission factor, crystal size effects
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination. https://app.cochat.ai/papers/10.1107/s1600576714022985
- The paper
- Krause, L., Herbst-Irmer, R., Sheldrick, G. M., & Stalke, D. (2015). Comparison of silver and molybdenum microfocus X-ray sources for single-crystal structure determination. Journal of Applied Crystallography. https://doi.org/10.1107/s1600576714022985
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.