A multipurpose instrument for time-resolved ultra-small-angle and coherent X-ray scattering
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
This article presents the main technical features and performance of the upgraded beamline ID02 at the ESRF. The beamline combines different small-angle X-ray scattering techniques in one unique instrument, enabling static and kinetic investigations from ångström to micrometre size scales and time resolution down to the sub-millisecond range. The main component of the instrument is an evacuated detector tube of length 34 m and diameter 2 m. Several different detectors are housed inside a motorized wagon that travels along a rail system, allowing an automated change of the sample–detector distance from about 1 to 31 m as well as selection of the desired detector. For optional combined wide-angle scattering measurements, a wide-angle detector is installed at the entrance cone of the tube. A scattering vector (of magnitude q) range of 0.002 ≤ q ≤ 50 nm−1 is covered with two sample–detector distances and a single-beam setting for an X-ray wavelength of 1 Å. In the high-resolution mode, two-dimensional ultra-small-angle X-ray scattering patterns down to q < 0.001 nm−1 can be recorded, and the resulting one-dimensional profiles have superior quality as compared to those measured with an optimized Bonse–Hart instrument. In the highest-resolution mode, the beam is nearly coherent, thereby permitting multispeckle ultra-small-angle X-ray photon correlation spectroscopy measurements. The main applications of the instrument include the elucidation of static and transient hierarchical structures, and nonequilibrium dynamics in soft matter and biophysical systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymer Science: A Comprehensive Reference
(2012) · Elsevier eBooks · doi:10.1016/c2009-1-28406-1 · Cited by 1,114
SASfit: a tool for small-angle scattering data analysis using a library of analytical expressions
Breßler, I., Kohlbrecher, J., & Thünemann, A. F. (2015) · Journal of Applied Crystallography · doi:10.1107/s1600576715016544 · Cited by 669 · cited 1×
“More advanced modeling is performed using specialized program suits such as SASfit (Breßler et al., 2015), SasView (Alina et al., 2017) and Irena (Ilavsky et al., 2018).”
MethodLabiche, J.-C., Mathon, O., Pascarelli, S., Newton, M. A., Ferre, G. G., Curfs, C., Vaughan, G., Homs, A., & Carreiras, D. F. (2007) · Review of Scientific Instruments · doi:10.1063/1.2783112 · Cited by 394 · cited 1×
“Therefore, a specific development was undertaken within the ESRF detector group to assemble a fast readout low-noise (FReLoN) detector (Labiche et al., 2007) based on a large-area Kodak CCD sensor (KAF-4320) bonded to a thick fiber-optic faceplate (50 50 mm) with 1:1 coupling (FReLoN 4M).”
MethodPyFAI, a versatile library for azimuthal regrouping
Kieffer, J., & Karkoulis, D. (2013) · Journal of Physics: Conference Series · doi:10.1088/1742-6596/425/20/202012 · Cited by 301 · cited 1×
“The second pipeline is based on Python fast azimuthal integration (pyFAI; Kieffer & Karkoulis, 2013).”
MethodUltra-small-angle X-ray scattering at the Advanced Photon Source
Ilavsky, J., Jemian, P. R., Allen, A. J., Zhang, F., Levine, L. E., & Long, G. G. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809008802 · Cited by 295 · cited 1×
“In this case, the USAXS setup involves a Bonse–Hart multi-crystal instrument (Sztucki & Narayanan, 2007; Ilavsky et al., 2009).”
MethodSAXS and USAXS on the high brilliance beamline at the ESRF
Narayanan, T., Diat, O., & Bösecke, P. (2001) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)00553-8 · Cited by 267 · cited 1×
“Traditionally, SAXS and wide-angle X-ray scattering (WAXS) experiments and ultra-small-angle X-ray scattering (USAXS) experiments have been performed using two separate instruments in tandem (Narayanan et al., 2001; Ilavsky et al., 2018).”
MethodSelf-citationIlavsky, J., Zhang, F., Andrews, R. N., Kuzmenko, I., Jemian, P. R., Levine, L. E., & Allen, A. J. (2018) · Journal of Applied Crystallography · doi:10.1107/s160057671800643x · Cited by 184 · cited 2×
“Traditionally, SAXS and wide-angle X-ray scattering (WAXS) experiments and ultra-small-angle X-ray scattering (USAXS) experiments have been performed using two separate instruments in tandem (Narayanan et al., 2001; Ilavsky et al., 2018).”
MethodPeptide nanotubes: molecular organisations, self-assembly mechanisms and applications
Valéry, C., Artzner, F., & Paternostre, M. (2011) · Soft Matter · doi:10.1039/c1sm05698k · Cited by 160 · cited 1×
“Examples range from complexities of hierarchically self-assembled biomimetic systems (Valéry et al., 2011) to pathways of cellular regulation (Piazzesi et al., 2018).”
BackgroundA review of X-ray intensity fluctuation spectroscopy
Sutton, M. (2007) · Comptes Rendus. Physique · doi:10.1016/j.crhy.2007.04.008 · Cited by 159 · cited 1×
“For these small sizes, the beam is highly coherent, producing speckles in the scattered field (Sutton, 2008).”
BackgroundLi, Y., Beck, R., Huang, T., Choi, M. C., & Divinagracia, M. (2008) · Journal of Applied Crystallography · doi:10.1107/s0021889808031129 · Cited by 158 · cited 1×
“The last guard slits are scatterless slits (Li et al., 2008) with hybrid metal/silicon crystal blades (Xenocs SA).”
Background
Cited by
Lombardo, D., & Kiselev, M. A. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14030543 · Cited by 718
Small-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Ricarte, R. G., Tournilhac, F., & Leibler, L. (2019) · Macromolecules · doi:10.1021/acs.macromol.8b02144 · Cited by 205
Myosin filament-based regulation of the dynamics of contraction in heart muscle
Brunello, E., Fusi, L., Ghisleni, A., Park-Holohan, S.-J., Ovejero, J. G., Narayanan, T., & Irving, M. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1920632117 · Cited by 129
“1-nm wavelength in a beam of size 300 μm (horizontal, full width at half-maximum) and 70 μm (vertical) at the sample position (38).”
Self-citationSynchrotron scattering methods for nanomaterials and soft matter research
Narayanan, T., & Konovalov, O. (2020) · Materials · doi:10.3390/ma13030752 · Cited by 60
“in situ and kinetic investigations [13].”
BackgroundInfluentialSelf-citationDi Cola, E., Cantu’, L., Brocca, P., Rondelli, V., Fadda, G. C., Canelli, E., Martelli, P., Clementino, A., Sonvico, F., Bettini, R., et al. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2019.110439 · Cited by 36
Probing Organic Thin Films by Coherent X-ray Imaging and X-ray Scattering
Patil, N., Narayanan, T., Michels, L., Skjønsfjell, E. T. B., Guizar-Sicairos, M., Van den Brande, N., Claessens, R., Van Mele, B., & Breiby, D. W. (2019) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b00324 · Cited by 6
“The measured SAXS patterns were normalized to an absolute intensity scale (units of sterad) using the standard procedure which includes detector dark-image correction, division by a flat field and intensity normalization.(26) Subsequently, the normalized patterns were azimuthally averaged to obtain the one-dimensional…”
BackgroundMethodSelf-citation
Metadata
- Authors
- Narayanan, T., Sztucki, M., Van Vaerenbergh, P., Léonardon, J., Gorini, J., Claustre, L., Sever, F., Morse, J., & Boesecke, P.
- Venue
- Journal of Applied Crystallography
- Published
- 2018-10-11
- Volume
- 51
- Issue
- 6
- Pages
- 1511-1524
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W2897318438
- Cited by
- 222
- References
- 29
- FWCI
- 26.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.