A high-flux automated laboratory small-angle X-ray scattering instrument optimized for solution scattering
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A commercially available small-angle X-ray scattering (SAXS) NanoSTAR instrument (Bruker AXS) with a liquid-metal-jet source (Excillum) has been optimized for solution scattering and installed at iNANO at Aarhus University. The instrument (named HyperSAXS) employs long high-quality parabolic Montel multilayer optics (Incoatec) and a novel compact scatterless pinhole slit with Ge edges, which was designed and built at Aarhus University. The combination of the powerful source and optimized geometry gives an integrated X-ray intensity close to 10 9 photons s−1 for a standard range of scattering vector moduli q = 0.0098–0.425 Å−1, where q = (4πsinθ)/λ and λ is the Ga K α wavelength of 1.34 Å. The high intensity of the instrument makes it possible to measure dilute samples of, for example, protein or surfactant with concentrations of 1 mg ml−1 in a few minutes. A flow-through cell, built at Aarhus University, in combination with an automated sample handler has been installed on the instrument. The sample handler is based on the commercial Gilson GX-271 injection system (Biolab), which also allows samples to be stored under thermostatted conditions. The sample handler inserts and removes samples, and also cleans and dries the sample cell between measurements. The minimum volume of the flow-through capillary is about 20 µl. The high intensity additionally allows time-resolved measurements to be performed with a temporal resolution of seconds. For this purpose a stopped-flow apparatus, (SFM-3000, Bio-Logic) was connected to the flow-through cell by high-performance liquid chromatography tubing. This configuration was chosen as it allows vacuum around the sample cell and thus maintains a low background. The instrument can readily be converted into a low-q setup with a q range of 0.0049–0.34 Å−1 and an X-ray intensity of about 5 × 10 7 photons s−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hubbell, J. H., & Seltzer, S. M. (1995) · doi:10.6028/nist.ir.5632 · Cited by 2,033
Cited by
Small-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Self-citationStructural and regulatory insights into the glideosome-associated connector from Toxoplasma gondii
Kumar, A., Vadas, O., Dos Santos Pacheco, N., Zhang, X., Chao, K., Darvill, N., Rasmussen, H. Ø., Xu, Y., Lin, G. M.-H., Stylianou, F. A., et al. (2023) · eLife · doi:10.7554/elife.86049 · Cited by 15
Self-citationStructural basis for kinase inhibition in the tripartite E. coli HipBST toxin-antitoxin system
(2022) · doi:10.1101/2022.01.28.478185 · Cited by 8
Structural basis for kinase inhibition in the tripartite E. coli HipBST toxin-antitoxin system
Bærentsen, R. L., Nielsen, S. V., Skjerning, R. B., Lyngsø, J., Bisiak, F., Pedersen, J. S., Gerdes, K., Sørensen, M. A., & Brodersen, D. E. (2023) · doi:10.7554/elife.90400.2 · Cited by 1
Self-citation
Metadata
- Authors
- Lyngsø, J., & Pedersen, J. S.
- Venue
- Journal of Applied Crystallography
- Published
- 2021-02-01
- Volume
- 54
- Issue
- 1
- Pages
- 295-305
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W3127830629
- Cited by
- 58
- References
- 1
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A high-flux automated laboratory small-angle X-ray scattering instrument optimized for solution scattering. https://app.cochat.ai/papers/10.1107/s1600576720016209
- The paper
- Lyngsø, J., & Pedersen, J. S. (2021). A high-flux automated laboratory small-angle X-ray scattering instrument optimized for solution scattering. Journal of Applied Crystallography. https://doi.org/10.1107/s1600576720016209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.