The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Hard X-ray fluorescence microscopy is one of the most sensitive techniques for performing trace elemental analysis of biological samples such as whole cells and tissues. Conventional sample preparation methods usually involve dehydration, which removes cellular water and may consequently cause structural collapse, or invasive processes such as embedding. Radiation-induced artifacts may also become an issue, particularly as the spatial resolution increases beyond the sub-micrometer scale. To allow imaging under hydrated conditions, close to the `natural state', as well as to reduce structural radiation damage, the Bionanoprobe (BNP) has been developed, a hard X-ray fluorescence nanoprobe with cryogenic sample environment and cryo transfer capabilities, dedicated to studying trace elements in frozen-hydrated biological systems. The BNP is installed at an undulator beamline at sector 21 of the Advanced Photon Source. It provides a spatial resolution of 30 nm for two-dimensional fluorescence imaging. In this first demonstration the instrument design and motion control principles are described, the instrument performance is quantified, and the first results obtained with the BNP on frozen-hydrated whole cells are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905 · cited 1×
“Sub-pixel registration was carried out with a zero-padded FFT approach on the corresponding sub-regions (Guizar-Sicairos et al., 2008), resulting in 64 vectors indicating the local offsets.”
MethodGorman, D. S., & Levine, R. P. (1965) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.54.6.1665 · Cited by 1,681 · cited 1×
“The wild-type strain of Chlamydomonas reinhardtii Dangeard (ATCC No. 18798, USA) was grown mixotrophically in a Tris-Acetate-Phosphate (TAP) medium (Gorman & Levine, 1965) at 296 K under constant illumination at a rate of 100 mmol m 2 s 1 and with continuous shaking of 120 r.p.m.”
MethodHandbook of X-Ray Spectrometry
(2001) · CRC Press eBooks · doi:10.1201/9780203908709 · Cited by 1,124 · cited 1×
“Data analysis, including both per-pixel fitting and elemental content quantification, was performed using MAPS software (Vogt, 2004), where the spectrum from each pixel collected from the sample was fitted with modified Gaussians (Van Grieken, 1992).”
MethodSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672 · cited 1×
“However, high-resolution X-ray microscopy inevitably involves a high radiation dose, causing radiationinduced bond breaking and consequent mass loss (Kirz et al., 1995; Beetz & Jacobsen, 2003; Nishino et al., 2009).”
BackgroundSelf-citationAn assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524 · cited 1×
“However, conventional sample preparation methods are not sufficient, in many cases, to preserve the ultrastructure of biological samples in X-ray imaging (Schneider, 1998; Howells et al., 2009).”
BackgroundSelf-citationWagner, D., Maser, J., Lai, B., Cai, Z., Barry, C. E., Höner zu Bentrup, K., Russell, D. G., & Bermudez, L. E. (2005) · The Journal of Immunology · doi:10.4049/jimmunol.174.3.1491 · Cited by 435 · cited 1×
“…(XFM) has opened remarkable opportunities for quantitative study of trace elements, particularly metals, within whole cells and tissue sections (Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al.,…”
BackgroundSelf-citationLow-Temperature Microscopy and Analysis
Echlin, P. (1992) · Springer eBooks · doi:10.1007/978-1-4899-2302-8 · Cited by 346 · cited 2×
“To avoid recrystallization of vitrified water, samples must be maintained at a temperature well below the glass transition of water at 135 K (for pure water) (Echlin, 1992) at all times.”
BackgroundThree-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction
Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.018101 · Cited by 306
Biology of TiO2–oligonucleotide nanocomposites
Paunesku, T., Rajh, T., Wiederrecht, G., Maser, J., Vogt, S., Stojićević, N., Protić, M., Lai, B., Oryhon, J., Thurnauer, M., et al. (2003) · Nature Materials · doi:10.1038/nmat875 · Cited by 300 · cited 2×
“(ii) TiO2–DNA nanocomposites (NCs) have been recently investigated as tools for nanobiotechnology (Paunesku et al., 2003, 2007); ‘next generation’ nanoparticles made as composites of Fe3O4 and TiO2 (Fe3O4@TiO2 nanocomposites) have been developed as well (Arora et al., 2012; Yuan et al., 2013).”
BackgroundMethodSelf-citationMAPS : A set of software tools for analysis and visualization of 3D X-ray fluorescence data sets
Vogt, S. (2003) · Journal de Physique IV (Proceedings) · doi:10.1051/jp4:20030160 · Cited by 298
Self-citationFahrni, C. J. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.02.039 · Cited by 297 · cited 1×
“…for quantitative study of trace elements, particularly metals, within whole cells and tissue sections (Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge &…”
BackgroundRismani-Yazdi, H., Haznedaroglu, B. Z., Bibby, K., & Peccia, J. (2011) · BMC Genomics · doi:10.1186/1471-2164-12-148 · Cited by 296
X‐ray fluorescence microprobe imaging in biology and medicine
Paunesku, T., Vogt, S., Maser, J., Lai, B., & Woloschak, G. (2006) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21047 · Cited by 251 · cited 1×
“…remarkable opportunities for quantitative study of trace elements, particularly metals, within whole cells and tissue sections (Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle &…”
BackgroundSelf-citationTwining, B. S., Baines, S. B., Fisher, N. S., Maser, J., Vogt, S., Jacobsen, C., Tovar-Sanchez, A., & Sañudo-Wilhelmy, S. A. (2003) · Analytical Chemistry · doi:10.1021/ac034227z · Cited by 249 · cited 1×
“(i) Green algae have been studied previously in a number of unique scientific contexts, such as biomineralization (Krejci et al., 2011), their potential use for carbon sequestration (Twining et al., 2003), and for production of biofuels (RismaniYazdi et al., 2011).”
BackgroundSelf-citationFinney, L., Mandava, S., Ursos, L., Zhang, W., Rodi, D., Vogt, S., Legnini, D., Maser, J., Ikpatt, F., Olopade, O. I., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607238104 · Cited by 197 · cited 1×
“…study of trace elements, particularly metals, within whole cells and tissue sections (Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge & Vogt, 2010;…”
BackgroundSelf-citationA hard X-ray nanoprobe beamline for nanoscale microscopy
Winarski, R. P., Holt, M. V., Rose, V., Fuesz, P., Carbaugh, D., Benson, C., Shu, D., Kline, D., Stephenson, G. B., McNulty, I., et al. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512036783 · Cited by 188 · cited 1×
“…with the aim of revealing and analyzing nanoscale structures and features in complex systems such as cells and tissues, advanced materials and devices (Bleuet et al., 2009; Matsuyama et al., 2010; Chu, 2010; Schroer et al., 2010; Somogyi et al., 2011; Winarski et al., 2012; Maser et al., 2013).”
BackgroundSelf-citationHard X-ray fluorescence tomography—an emerging tool for structural visualization
de Jonge, M. D., & Vogt, S. (2010) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2010.09.002 · Cited by 172 · cited 1×
“…(Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge & Vogt, 2010; Fittschen & Falkenberg, 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012).”
Self-citationQuantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution
de Jonge, M. D., Holzner, C., Baines, S. B., Twining, B. S., Ignatyev, K., Diaz, J., Howard, D. L., Legnini, D., Miceli, A., McNulty, I., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001469107 · Cited by 161 · cited 1×
“By using XFM with 400 nm spatial resolution, a recent study on dehydrated freshwater diatom revealed surprising metal distributions, particularly the ringlike structures formed by the distributions of manganese and iron in the siliceous cell wall (de Jonge et al., 2010).”
BackgroundSelf-citationOrtega, R., Devès, G., & Carmona, A. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0166.focus · Cited by 150 · cited 2×
“…oxidation state of elements, can be elucidated using X-ray fluorescence spectroscopy and X-ray absorption nearedge structure (XANES) (Norman, 1986; Dyar et al., 1998; Ortega et al., 2009; Gorman-Lewis et al., 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012; Oakes et al., 2012).”
BackgroundPaunesku, T., Vogt, S., Lai, B. C. H., Maser, J. M., Stojićević, N., Thurn, K. T., Osipo, C., Liu, H. S., Legnini, D. G., Wang, Z., et al. (2007) · Nano Letters · doi:10.1021/nl0624723 · Cited by 124 · cited 2×
“(ii) TiO2–DNA nanocomposites (NCs) have been recently investigated as tools for nanobiotechnology (Paunesku et al., 2003, 2007); ‘next generation’ nanoparticles made as composites of Fe3O4 and TiO2 (Fe3O4@TiO2 nanocomposites) have been developed as well (Arora et al., 2012; Yuan et al., 2013).”
BackgroundMethodSelf-citationYuan, Y., Chen, S., Paunesku, T., Gleber, S. C., Liu, W. C., Doty, C. B., Mak, R., Deng, J., Jin, Q., Lai, B. C. H., et al. (2013) · ACS Nano · doi:10.1021/nn4033294 · Cited by 122 · cited 3×
“(ii) TiO2–DNA nanocomposites (NCs) have been recently investigated as tools for nanobiotechnology (Paunesku et al., 2003, 2007); ‘next generation’ nanoparticles made as composites of Fe3O4 and TiO2 (Fe3O4@TiO2 nanocomposites) have been developed as well (Arora et al., 2012; Yuan et al., 2013).”
BackgroundMethodSelf-citationOakes, M. M., Weber, R. J., Lai, B. C. H., Russell, A. G., & Ingall, E. D. (2012) · Atmospheric chemistry and physics · doi:10.5194/acp-12-745-2012 · Cited by 116 · cited 1×
“…oxidation state of elements, can be elucidated using X-ray fluorescence spectroscopy and X-ray absorption nearedge structure (XANES) (Norman, 1986; Dyar et al., 1998; Ortega et al., 2009; Gorman-Lewis et al., 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012; Oakes et al., 2012).”
BackgroundSelf-citationNanocarriers Enhance Doxorubicin Uptake in Drug-Resistant Ovarian Cancer Cells
Arora, H., Jensen, M. P., Yuan, Y., Wu, A., Vogt, S., Paunesku, T., & Woloschak, G. E. (2011) · Cancer Research · doi:10.1158/0008-5472.can-11-2890 · Cited by 109 · cited 2×
“(ii) TiO2–DNA nanocomposites (NCs) have been recently investigated as tools for nanobiotechnology (Paunesku et al., 2003, 2007); ‘next generation’ nanoparticles made as composites of Fe3O4 and TiO2 (Fe3O4@TiO2 nanocomposites) have been developed as well (Arora et al., 2012; Yuan et al., 2013).”
BackgroundMethodSelf-citationQuantitative Phase Imaging with a Scanning Transmission X-Ray Microscope
de Jonge, M. D., Hornberger, B., Holzner, C., Legnini, D. G., Paterson, D. J., McNulty, I., Jacobsen, C. J., & Vogt, S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.163902 · Cited by 104 · cited 1×
“Downstream of the optics train and sample stage assembly, a quadrant photodiode (AXUV, Opto Diode, USA) allows differential phase contrast signals to be collected simultaneously with the X-ray fluorescence signal (de Jonge et al., 2008; Hornberger et al., 2008).”
BackgroundSelf-citationElemental mapping of frozen‐hydrated cells with cryo‐scanning X‐ray fluorescence microscopy
Matsuyama, S., Shimura, M., Fujii, M., Maeshima, K., Yumoto, H., Mimura, H., Sano, Y., Yabashi, M., Nishino, Y., Tamasaku, K., et al. (2010) · X-Ray Spectrometry · doi:10.1002/xrs.1256 · Cited by 97 · cited 1×
“…with the aim of revealing and analyzing nanoscale structures and features in complex systems such as cells and tissues, advanced materials and devices (Bleuet et al., 2009; Matsuyama et al., 2010; Chu, 2010; Schroer et al., 2010; Somogyi et al., 2011; Winarski et al., 2012; Maser et al., 2013).”
BackgroundBiomedical applications of the ESRF synchrotron-based microspectroscopy platform
Bohic, S., Cotte, M., Salome-Pateyron, M., Fayard, B., Kühbacher, M., Cloetens, P., Martínez‐Criado, G., Tucoulou, R., & Susini, J. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.006 · Cited by 91 · cited 2×
“…(Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge & Vogt, 2010; Fittschen & Falkenberg, 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012).”
BackgroundA hard x-ray nanoprobe for scanning and projection nanotomography
Bleuet, P., Cloetens, P., Gergaud, P., Mariolle, D., Chevalier, N., Tucoulou, R., Susini, J., & Chabli, A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3117489 · Cited by 85 · cited 1×
“…with the aim of revealing and analyzing nanoscale structures and features in complex systems such as cells and tissues, advanced materials and devices (Bleuet et al., 2009; Matsuyama et al., 2010; Chu, 2010; Schroer et al., 2010; Somogyi et al., 2011; Winarski et al., 2012; Maser et al., 2013).”
BackgroundDifferential phase contrast with a segmented detector in a scanning X-ray microprobe
Hornberger, B., de Jonge, M. D., Feser, M., Holl, P., Holzner, C., Jacobsen, C. J., Legnini, D. G., Paterson, D. J., Řehák, P., Strüder, L., et al. (2008) · Journal of Synchrotron Radiation · doi:10.1107/s0909049508008509 · Cited by 83
Self-citationTrends in environmental science using microscopic X-ray fluorescence
Fittschen, U. E. A., & Falkenberg, G. (2011) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2011.06.006 · Cited by 82 · cited 1×
“…(Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge & Vogt, 2010; Fittschen & Falkenberg, 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012).”
Selectivity in biomineralization of barium and strontium
Krejci, M. R., Wasserman, B., Finney, L. A., McNulty, I., Legnini, D. G., Vogt, S., & Joester, D. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.08.006 · Cited by 75 · cited 1×
“(i) Green algae have been studied previously in a number of unique scientific contexts, such as biomineralization (Krejci et al., 2011), their potential use for carbon sequestration (Twining et al., 2003), and for production of biofuels (RismaniYazdi et al., 2011).”
BackgroundSelf-citationQuantitative imaging of metals in tissues
Ralle, M., & Lutsenko, S. (2009) · BioMetals · doi:10.1007/s10534-008-9200-5 · Cited by 65 · cited 1×
“…(Wagner et al., 2005; Paunesku et al., 2006; Fahrni, 2007; Finney et al., 2007; Szczerbowska-Boruchowska, 2007; Ortega et al., 2009; Paunesku et al., 2009; Ralle & Lutsenko, 2009; de Jonge & Vogt, 2010; Fittschen & Falkenberg, 2011; Bohic et al., 2012; Jensen et al., 2012; Vogt & Ralle, 2012).”
Cryo‐electron tomography: methodology, developments and biological applications
Vanhecke, D., Asano, S. M., Kochovski, Z., Fernández‐Busnadiego, R., Schrod, N., Baumeister, W. P., & Lučić, V. (2010) · Journal of Microscopy · doi:10.1111/j.1365-2818.2010.03478.x · Cited by 58
Vogt, S., & Ralle, M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6437-1 · Cited by 45
Self-citationFe (super 3+) distribution in oxidized olivine; a synchrotron micro-XANES study
Dyar, M., Delaney, J. S., Sutton, S. R., & Schaffer, M. W. (1998) · American Mineralogist · doi:10.2138/am-1998-11-1227 · Cited by 35
X‐ray fluorescence spectrometry, an analytical tool in neurochemical research
Szczerbowska‐Boruchowska, M. (2007) · X-Ray Spectrometry · doi:10.1002/xrs.1007 · Cited by 34
Shu, D., Maser, J. M., Holt, M. V., Winarski, R. P., Preissner, C., Smolyanitskiy, A., Lai, B. C. H., Vogt, S., & Stephenson, G. B. (2007) · AIP conference proceedings · doi:10.1063/1.2436307 · Cited by 26 · cited 1×
“This approach minimizes positional changes due to the change in pressure and resulting changes of the instrument chamber (Shu et al., 2004, 2007).”
BackgroundSelf-citation
Cited by
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
ID16B: a hard X-ray nanoprobe beamline at the ESRF for nano-analysis
Martínez-Criado, G., Villanova, J., Tucoulou, R., Salomon, D., Suuronen, J.-P., Labouré, S., Guilloud, C., Valls, V., Barrett, R., Gagliardini, E., et al. (2016) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515019839 · Cited by 263
Que, E. L., Bleher, R., Duncan, F. E., Kong, B. Y., Gleber, S. C., Vogt, S., Chen, S., Garwin, S. A., Bayer, A. R., Dravid, V. P., et al. (2015) · Nature Chemistry · doi:10.1038/nchem.2133 · Cited by 237
Self-citationPhase retrieval by coherent modulation imaging
Zhang, F., Chen, B., Morrison, G. R., Vila-Comamala, J., Guizar-Sicairos, M., & Robinson, I. K. (2016) · Nature Communications · doi:10.1038/ncomms13367 · Cited by 216
Alfeld, M., & Janssens, K. (2015) · Journal of Analytical Atomic Spectrometry · doi:10.1039/c4ja00387j · Cited by 184
Metadata
- Authors
- Chen, S., Deng, J., Yuan, Y., Flachenecker, C., Mak, R., Hornberger, B., Jin, Q., Shu, D., Lai, B., Maser, J., Roehrig, C., Paunesku, T., Gleber, S. C., Vine, D. J., Finney, L., VonOsinski, J., Bolbat, M., Spink, I., Chen, Z., Steele, J., Trapp, D., Irwin, J., Feser, M., Snyder, E., Brister, K., Jacobsen, C., Woloschak, G., & Vogt, S.
- Venue
- Journal of Synchrotron Radiation
- Published
- 2013-12-12
- Volume
- 21
- Issue
- 1
- Pages
- 66-75
- ISSN
- 0909-0495 (ISSN-L)
- 1600-5775
- OpenAlex
- W2170780719
- Cited by
- 177
- References
- 36
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.